Operating Instructions - Heat & Glo SL-550TRSI-AUE Installation And Operation Instructions Manual

Hearth and home technologies heater manual sl-550trsi-aue
Hide thumbs Also See for SL-550TRSI-AUE:
Table of Contents

Advertisement

2.0 OPERATING INSTRUCTIONS

This appliance is a balanced flue heater and is designed
to operate with all combustion air being siphoned from
the outside of the building and all exhaust gases ex-
pelled to the outside of the building.
WARNING:
THIS UNIT IS NOT FOR USE
!
WITH SOLID FUEL.
The control system for this model includes a pilot, elec-
tronic module, spark ignitor and thermocouple. It con-
sists of a 6V gas control valve/variable regulator and
an remote control. The controls are located in the lower
compartment behind the lower door, and access is
gained by lifting the door up. See Figure 1.
WARNING:
DO NOT CONNECT 240 VAC
!
TO THE GAS CONTROL VALVE OR CON-
TROL WIRING SYSTEM OF THIS UNIT.
When lit for the first time, the appliance will emit a slight
odor for an hour or two, due to paint and lubricants used
in the manufacturing process. For the first few minutes
after each lighting, vapor may condense and fog the
glass and the flames may be blue. After a few minutes
this moisture will disappear and within 15-30 minutes
the flames should become yellow.
The heater may produce a noise, caused from metal
expansion and contraction as it heats up and cools down.
This noise is similar to one that a furnace or heat duct
may produce and does not affect the operation or lon-
gevity of the heater.
OPERATING
CAUTIONS
• THIS APPLIANCE
MAY EXHIBIT A
SLIGHT CARBON
DEPOSITION.
• DO NOT PLACE
ARTICLES ON OR
AGAINST THIS
APPLIANCE.
• DO NOT USE OR
STORE FLAM-
MABLE MATERI-
ALS NEAR THIS
APPLIANCE.
• DO NOT SPRAY
AEROSOLS IN
THE VICINITY OF
THIS APPLIANCE
WHILE IT IS IN
OPERATION.
30
PILOT
IGNITION MODULE
6VDC
BATTERY PORT
ON/OFF
SWITCH
Figure 36.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06
• THE DRESS GUARD IS FITTED TO THIS APPLI-
ANCE TO REDUCE THE RISK OF FIRE OR INJURY
FROM BURNS AND NO PART OF IT SHOULD BE
PERMANENTLY REMOVED. FOR PROTECTION
OF YOUNG CHILDREN OR THE INFIRM, A SEC-
ONDARY GUARD IS REQUIRED.
• THE GLASS DOOR ASSEMBLY MUST BE IN
PLACE AND SEALED AND THE FIXED MESH
DRESS GUARD MUST BE IN PLACE ON THE
FIREPLACE BEFORE THE UNIT CAN BE PLACED
INTO SAFE OPERATION.
• DO NOT USE THIS APPLIANCE IF ANY PART
HAS BEEN UNDER WATER. IMMEDIATELY CALL
A QUALIFIED SERVICE TECHNICIAN TO INSPECT
THE UNIT AND TO REPLACE ANY PART OF THE
CONTROL SYSTEM AND ANY GAS CONTROL
WHICH HAS BEEN UNDERWATER.
• DO NOT OPERATE THIS APPLIANCE WITH THE
GLASS DOOR REMOVED, CRACKED, OR BRO-
KEN. REPLACEMENT OF THE GLASS DOOR
SHOULD BE DONE BY A LICENSED OR QUALI-
FIED PERSON. DO NOT STRIKE OR SLAM THE
GLASS DOOR.
• THE GLASS DOOR ASSEMBLY SHALL ONLY BE
REPLACED AS A COMPLETE UNIT AS SUPPLIED
BY THE GAS FIREPLACE MANUFACTURER. NO
SUBSTITUTE MATERIALS MAY BE USED.
FLAME SPARKER/
SENSOR
VALVE
REMOTE
CONTROL
ANT.
WALL SWITCH
IGNITION
MODULE
GROUND
NEUTRAL
THERMOCOUPLE
BLOCK
(CONNECTED TO
BACK OF VALVE)
VALVE
GAS LINE
CONNECTED TO
BACK OF VALVE
ON/OFF
(6V)
HOT
PLUG IN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents