Installing Mezzanine Cards - HP Integrity BL860c User's & Service Manual

Server blade
Hide thumbs Also See for Integrity BL860c:
Table of Contents

Advertisement

1.
Locate the DIMM slots on the server blade system board.
See
Figure
NOTE:
Figure 15 DIMM Slot Locations
2.
Ensure the DIMM slot latches are open.
CAUTION:
adversely affect data integrity.
DIMMs do not seat fully if turned the wrong way.
DIMMs in a pair must be identical.
3.
Insert a DIMM in a slot and push down firmly until the latches click shut.

Installing Mezzanine Cards

The server blade has three ports for mezzanine cards on the system board. These cards provide
I/O capabilities for the server blade. The server supports one Type I mezzanine card, and two
Type II mezzanine cards.
The Type I mezzanine port supports an Intel PCIe x4 card
The Type II mezzanine ports support Intel PCIe x8 cards
For more information regarding the different cards supported by the BL860c server blade, see
http://h71028.www7.hp.com/enterprise/cache/316682-0-0-0- 1 21.html?
jumpid=reg_R1002_USEN.
The available power rails for the mezzanine cards are 12 V, 3.3 V, and 3 V auxiliary, with a total
power of 25 W for each card.
Figure 16
shows the mezzanine port locations on the system board.
15.
The server blade ships with at least two DIMMs installed in slots 0A and 0B.
Use only HP low profile (1.2 in.) DIMMs. DIMMs from other sources might
Installing Additional Components
33

Advertisement

Table of Contents
loading

Table of Contents