Turning The System On, With Points Open (Bypassing Points) - Bosch D220 User Manual

Security system
Table of Contents

Advertisement

Turning the System On, with Points Open
(Bypassing Points)
I have this feature.
I do not have this feature.
Use this feature to selectively exclude points you do not wish to turn on
with the rest of the system. For example, you may wish to bypass the
patio door while turning on the remainder of the system.
1.
Press the [9] or [0] key to turn the system All or Part On.
2.
If a point is faulted, the error tone sounds and the point light for
the faulted point blinks. In this example, point 5 is faulted.
3.
Press the key for the point you want to bypass. In this example,
you would press the [5] key. The point light goes off. The exit
tone starts when all faulted points are bypassed.
4.
If you bypass a point in error, press [CLEAR] and start over at
step 1.
5.
Exit now or turn the system on with no delay by pressing [9] or
[0] a second time.
6.
When exit delay time expires, the keypad beeps three times and
the system turns on. The All or Part light and OK light blink to
indicate that the system is on with points bypassed.
7.
Turning the system off clears all bypassed points.