INSPECTION
Perform the tests below to ensure proper operation of the GFCI receptacle.
Record your test on the GFCI test card provided on the generator.
Before each use:
If the generator is stored outdoors, unprotected from the weather, test the
GFCI receptacle before each use as described in the monthly inspection.
Monthly:
Under normal operating conditions, perform the GFCI test monthly.
1. Unplug all appliances
from the
generator.
2. Start the engine.
3. Turn the circuit breaker ON.
4. Make sure the auto-throttle switch
is OFF
5. Press the TEST BUTTON
-The
RESET BUTTON should
extend with a click.
-If
the REST BUTTON does not
extend, contact an authorized
Honda generator dealer.
TEST BUlTON