Thermostat; Remote Control - Harman Stove Company HB 38 DV Installation And Operating Manual

Harman stoves direct vent gas fireplace installation and operating manual serenityiii hb38dv i
Table of Contents

Advertisement

Only For Qualified Installers

Thermostat

Rear Burner
Button
INSTALLATION (Options)
Connecting the
Optional Thermostat
plugged into the terminal strip located in the lower
left front corner of the heater.
only a special low resistance thermostat. DO NOT
USE A REGULAR HEATING THERMOSTAT.
free from corrosion, and tight. Inspect connections
periodically to confirm that no corrosion has built
up over time.
livolt control system should give many years of
trouble-free service.
for the length of the wire:
Front Burner

Remote Control

Button
used to turn the front burner on and off. The rear
button is used to turn the rear burner on and off.
and does not need to be pointed directly at the fire-
place.
ing bracket and all wiring are included when you
order the remote control.
kit.
28
If the optional thermostat is used, it must be
When installing a millivolt control system, use
Be sure that all electrical connections are clean,
When properly installed and maintained, a mil-
It is important to use wire of a gauge proper
RECOMMENDED WIRE GAUGES
Maximum
Wire
Length
Gauge
100'
14
60'
16
40'
18
25'
20
15'
22
The front button on the remote control can be
This remote uses the ultrasonic control method
A hand held sending unit, receiving unit, mount-
Installation instructions are packed with remote

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Serenity iii