Troubleshooting; Please Read The Following Carefully - Central Pneumatic 95630 Set Up And Operating Instructions Manual

Compressor and air brush kit
Table of Contents

Advertisement

clean and wipe down Airbrush and all
that were used during operation.
3.
AFTER EVERY 500 HOURS OF
REGULAR USE, replace Compression

Troubleshooting

Problem
Air Compressor
1. No power at outlet.
will not start.
2. Cord not connected.
Pressure is low
1. Air connection is leaking.
causing a weak
2. Air Hose is broken.
spray at Nozzle of
3. Screws on cylinder cover is
Air Brush.
Poor atomization
1. The air connection is leaking.
when using Air
2. Paint viscosity is too thick.
Brush.
3. The Air Brush nozzle is
Air Compressor is
1. Valve plate is unscrewed or
running well but
no air pressure is
2. Retainer ring is destroyed by
being delivered to
Air Brush.
The Compressor
1. Electric cord is broken.
motor does not
2. Connections inside the
work.
3. The on - off switch is
Compressor
1. Exhaust outlet is totally
motor makes a
sound, but does
2. Cylinder valve is incorrectly
not run.
The Compressor
Bearing is loose or damaged.
motor runs but is
making irregular
or knocking noise.
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect air supply before service.

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL
ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR
SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN
FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN
BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER
REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT
PARTS THERETO.
SKU 95630
Possible Causes
loose.
plugged or dirty.
out of place.
continued use.
compressor are defective.
defective.
blocked.
fitted. Possibly it is mounted
in the wrong direction.
For technical questions, please call 1‑800‑444‑3353.
Ring and Inlet and Outlet Valves. Please
note: This work should only be done by
a qualified service technician.
Likely Solutions
1. Check power at outlet.
2. Check that cord is plugged in.
1. Seal air connection with plumbers tape, (only for
non-flammable type connections).
2. Replace air connection if necessary.
3. Tighten Cylinder Cover screws.
1. Make sure all air connections are "air-tight".
2. Add correct solvent for type of paint you are using
and mix thoroughly.
3. Wash the Air Brush nozzle or change it if necessary.
1. Open the front cover and tighten all screws while
making sure the valve plate is in the correct position.
2. Replace the retainer ring if necessary.
1. Check the electric cord and replace it if necessary.
2. Open the rear plate and check the connections.
Repair them if necessary.
3. Check the operation of the on - off switch and
replace if necessary.
1. Open the outlet cap and unblock the exhaust.
2. Re-assemble making sure the cylinder valve is
correctly fitted.
Replace the bearing if necessary.