10.7.2 Lower glass
1
Disconnect the power cord.
2
Lift the top cover release lever (1) and open
the top cover (2).
Important:
L Close the manual input tray (3) before
opening the top cover.
1
4
Caution:
The fuser unit (4) gets hot. Do not
touch it.
Note:
L Do not touch the transfer roller (5).
3
Remove the drum and toner unit (1) by
holding the tabs.
1
4
Clean the lower glass (1) with a soft and dry
cloth.
2
5
5
Reinstall the drum and toner unit (1) by
holding the tabs.
3
L Make sure that the triangles (2) match to
1
1
install the drum and toner unit correctly.