4.
5.
Drill two %" (3.0 mm) holes that correspond to the bracket
holes of the determined mounting method. See the following
illustrations.
Floor Mounting
Wall Mounting
A. #12 x 1%" screws
B. Anti-tip bracket
A. #12 x 1%" screws
B. Anti-tip bracket
Using a Phillips screwdriver, mount anti-tip bracket to the wall
or floor with the two #12 x 1s/8 '' screws provided.
Explosion Hazard
Use a new CSA International
approved
gas supply
line.
instal
a shut=off valve.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified
person include:
licensed
heating personnel,
authorized
gas company
personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
3=
Use a 15Ae" c ombination
wrench and an adjustable wrench to
attach the flexible connector to the adapters. Check that
connector is not kinked.
..............
A
r
i
A. Gas pressure regulator
B. Use pipe-joint
compound.
C. Adapter (must have Y2"male
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F Y2" or 3/4"gas pipe
G. Use pipe-joint
compound.
H. Adapter
4. Gas supply pipe must be located within the shaded area as
shown in the "Cabinet Dimensions"
illustration in "Location
Requirements"
section.
A
A. Gas pressure regulator
B. Adapter
C. Flexible connector
D. Manual shutoff valve
Complete
connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
Typical flexible
connection
1. Apply pipe-joint compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
2=
A. Closed valve
B. Open valve
Test all connections
by brushing on an approved
noncorrosive
leak-detection
solution. If bubbles appear, a
leak is indicated. Correct any leak found.
8