Download Print this page

KitchenAid KDRS505XSS03 Installation Instructions Manual page 53

30" (76.2 cm) double oven dual fuel ranges

Advertisement

Available languages

Available languages

3.
6. Use 3/8"nut driver to connect the neutral (white) lug to the
center terminal block post with one of the 10-32 hex nuts.
Pull the conduit through the strain relief on cord/conduit
plate
on bottom of range. Allow enough slack to easily attach
wiring to the terminal block.
................... ,,,,,
................
i"_2_ i_
"i_/"
"
.....
.............. I
_
i........
ii
i
i
C
4.
G
F
D
A. Terminal block
B. Ground-link
screw
C. Cord/conduit
plate
D. Line 2 (red) wire
E. Neutral (white) wire
F. Line 1 (black) wire
G. Bare (green) ground wire
Attach terminal lugs (located in the package containing
literature) to line 1 (black), neutral (white), and line 2 (red)
wires. Loosen (do not remove) the setscrew on the front of
the terminal lug and insert exposed wire end through bottom
of terminal lugs. Securely tighten setscrew to XX Ibs-in.
torque. See Bare Wire Torque Specifications
chart.
C
E
A. Terminal lug
B. Setscrew
C. Line 1 (black) wire
D. Neutral (white) wire
E. Line 2 (red) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 Ibs-in. (2.3 N-m)
Wire Awg
Torque
8 gauge copper
25 Ibs-in. (2.8 N-m)
6 gauge aluminum
35 Ibs-in. (4.0 N-m)
5.
Use Phillips screwdriver to connect the bare (green) ground
wire to the range with the ground-link
screw. The ground wire
must be attached first and must not contact any other
terminal.
B
/
c
D
_ F
E
A. 10-32 hex nut
B. Line 1 (black)
C. Bare (green) ground wire
D. Ground-rink screw
E. Neutral (white) wire
F. Line 2 (red)
G. Terminal lug
7. Connect line 1 (black) and line 2 (red) terminal lugs to the
outer terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
3-wire connection:
Direct Wire
Use this method only if local codes permit connecting
ground
conductor to neutral supply wire.
1. Pull the conduit through the hole and conduit plate on bottom
of range. Allow enough slack to easily attach the wiring to the
terminal block.
F
A. Terminal block
B. Ground-link
screw
C. Cord/conduit
plate
D. Line 2 (red) wire
E. Bare (green) ground wire
F. Line 1 (black) wire
13

Advertisement

loading