KitchenAid KDRS505XSS00 Installation Instructions Manual page 19

30" (76.2 cm) double oven dual fuel ranges
Hide thumbs Also See for KDRS505XSS00:
Table of Contents

Advertisement

Available languages

Available languages

GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.
Explosion Hazard
Use a new CSA International
approved
gas supply line.
instal a shut=off valve.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified
person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip
bracket to rear range foot.
Reconnect
the anti-tip
bracket,
if the range is moved.
Failure to follow these instructions can result in death
or serious
burns to children
and adults.
1. Turn manual shutoff valve to the closed position.
To Convert Gas Pressure Regulator
1. Locate gas pressure regulator at the rear of the range.
2.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
Unscrew the hex-shaped regulator cap from the regulator and
remove the regulator pin.
A
\
B
A. Regulator pin
B. Regulator cap
3. Flip the regulator pin over and snap pin firmly into place.
A
4.
A. Natural gas position
B. LP gas position
Screw the hex-shaped regulator cap securely back into place.
Do not overtighten.
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
2. Unplug range or disconnect power.