Connection To The Range - Kenmore 79041112200 Installation Instructions Manual

30" electric slide-in range
Table of Contents

Advertisement

Available languages

Available languages

Electrical Connection to the Range
This appliance
is manufactured
with the neutral
terminal
connected
to the frame.
Three
Conductor
Wire Connection
to Range
If local codes permit connection
of the frame
grounding
conductor
to the neutral wire of the
copper
power supply cord (see Fig. 3):
1. Remove the 3 screws at the lower end of the
rear wire cover, then bend the lower end of the
rear wire cover (access cover) upward
to expose
range terminal
connection
block (see Fig. 2).
2.Using the nuts supplied
in the literature
package,
connect
the neutral
of copper
power supply
cord to the center silver-colored
terminal
of the
terminal
block, and connect
the other wires to
the outer terminals.
Match
wires and terminals
by
color (red wires connected
to the right terminal,
black wires connected
to the left terminal)
(see
Fig. 3).
3.Lower the terminal
cover and replace
the 3
screws.
Silver colored Terminal
Red wire
Four Conductor
Wire Connection
to Range
Where
local codes does NOT permit connection
of
the frame
grounding
conductor
to the neutral
wire
of the copper
power supply cord (see Fig. 4)
1. Remove the 3 screws at the lower end of the
rear wire cover, then raise the lower end of the
rear wire cover (access cover) upward
to expose
range terminal
connection
block (see Fig. 2).
2. Remove the ground
strap from the terminal
block
and from the appliance
frame.
3.Using the nuts supplied
in the literature
package,
connect
the ground
wire (green) of copper
power
supply cord to the frame
of the appliance
with
the ground
screw, using the hole in the frame
where the ground
strap was removed
(see Fig. 4).
4.Connect
the neutral
of the copper
power supply
cord to the center silver-colored
terminal
of the
terminal
block, and connect
the other wires to
the outer terminals.
Match
wires and terminals
by
color (red wires connected
to the right terminal,
black wires connected
to the left terminal).
5.Lower the terminal
cover and replace
the 3
screws.
Block
Colored
Terminal
Wire
Terminal
--
Block
Black
wire
A strainrelief
supplied
by the user
must be installed at
this location
ro 240 V
receptacle
Figure 3
1-1/8"
Dia,
Direct
Connection
Hole. Punch
out knockout
for 1-3/8"
Dia,
Cord Kit Hole
Black
1-1/8"
Direct
Connection
Hole. Punch
out knockout
for 1-3/8"
Dia.
Cord Kit Hole
A strainrelief
supplied
by the user
must be installed
at
-To 240 V receptacle
this location
NOTE: Be sure to remove the supplied
!_l
grounding
strap
Figure 4
7

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

7904111320079041119200

Table of Contents