Thermador VCI21CS/01 Installation Manual page 6

Vci2 series ventilation hood
Table of Contents

Advertisement

Available languages

Available languages

Installation
Preparation
Electrical Requirements
Mounting Requirements
The unit requires a 120V AC, 60Hz. 15A branch circuit. For future service, install
the outlet in an easily accessible location.
The unit must be mounted to the surrounding housing. See "General Information"
on page 3 for suggestions for determining hood height.
For best results, install the unit as far up in the housing or hood as possible. This
will improve the function of the appliance.
When calculating the load for the housing support system, be sure to include the
weight of the ventilation unit. See "Ventilation Unit Weight" on page 4. for unit
weight by model.
Table 1: Ventilation Unit Weight
21" (53 cm)
18 1/4 lbs. (8.3 kg)
29" (73 cm)
19 Ibs. (8.7 kg)
For proper performance, the housing must cover the entire cooking surface.
Build housing to correspond with Figure 7: Housing Cutout Dimensions - 20 718"
(53 cm) models or Figure 8: Housing Cutout Dimensions - 28 314" (73 cm) mod-
els.
Figure 7: Housing Cutout Dimensions - 20 7/8" (53 cm) models