MODEL HMWB36FS SHOWN WITH 36-INCH GAS COOKTOP SGSX365FS...
Page 2
From standard wall to specialty hoods, downdrafts, island and custom inserts, each model has one thing in common: legendary Thermador performance. These powerful, quiet systems tackle unwanted smoke, grease, heat and odors—quietly and ef ciently—with ventilation power ranging from 400 to 1,300 CFM.
Page 3
48" VCI248Ds The width of the hood should equal that of the cooktop or rangetop or exceed it by 3 inches on either side. Install these hoods only with Thermador blowers. *High heat tested to accommodate Pro Harmony™ or Pro Rangetop 18,000 burners and grill.
Page 4
VENTILATION RANGE, RANGETOp AND VENTILATION MATRIX pROFESSIONAL SERIES 36-INCH 48-INCH 30-INCH 36-INCH 48-INCH PRO HARMONY PRO HARMONY RANGETOP RANGETOP RANGETOP 24-INCH DEPTH 24-INCH DEPTH 1.800.735.4328 | THERMADOR.COM...
Page 5
CuSTOM INSErTS 29" VCI29CS 42" HGSI42TS ISLAND HOOD The width of the hood should equal that of the cooktop or rangetop or exceed it by 3 inches on either side. install these hoods only with Thermador blowers. 30-INCH 36-INCH INDuCTION...
Page 6
VENTILATION COOKTOP AND VENTILATION MATRIX MASTERPIECE® SERIES 30-INCH 30-INCH 36-INCH 36-INCH ELECTrIC COOKTOP SENSOr ELECTrIC COOKTOP ELECTrIC COOKTOP SENSOr ELECTrIC COOKTOP 1.800.735.4328 | THERMADOR.COM...
Page 7
HMCN_FS CHIMNEY HOODS HMCB_FS HGEW36FS HDDW36FS HGSI42TS ISL ND HOODS VCI_CS CUSTOM INSERTS DOWNDR FT UCVM_FS *Purchase separately at most hardware stores, unless otherwise indicated with a Thermador model number. Available Sizes (Widths) 600 1000 600 • 30", 36", 42", 1000 • 48", 54" 1300 •...
• ll stainless steel or stainless steel with glass designs available ISLAND HOODS Thermador island hoods offer excellent overall efficiency in drawing away smoke, moisture and heat. • n option for when a wall surface is not available • Push button controls CUSTOm INSERTS To create a seamless design with wall or island applications, use custom hood inserts.
Page 11
MODEL HPWB48FS SHOWN WITH 48-INCH PRO HARMONY® RANGE PRD486GDHU AND 36-INCH WARMING DRAWER WDF30EP...
VENTILATION WALL HOODS Thermador Wall Hoods put the finishing touch on your cooking system, with deep capture areas for the best overall efficiency in drawing away smoke, moisture and heat. These elegant hoods combine style with vigorous performance, generating ventilation power from 600 to 1,300 CFM. vailable in a variety of heights, widths and depths, they accommodate your individual venting needs.
Hold dishes at serving temperature on our optional Keep-Hot Shelf. PH30CS, PH36CS, PH42CS, PH48CS and PH54CS only) ELECTRICAL SPECIFICATIONS Be sure your Thermador Wall Hood is properly installed and grounded by a qualified technician. Installation, electrical connections and grounding must comply with all applicable local codes.
The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area. If using a 10" duct, Thermador recommends not exceeding 150 feet of duct. Transitions, elbows and wall or roof caps are all factors that will add more static pressure, therefore increasing your equivalent duct run.
VENTILATION INSTALLATION OPTIONS Thermador Wall Hoods may be installed above a Thermador Cooktop or Range to create a convenient cooking center. Refer to the appropriate section for additional specifications. Hood installation height above a cooktop or range can vary. To obtain the necessary installation height above a Thermador Professional Cooktop or Range, consult the appliance's installation manual.
Page 17
VENTILATION 24-INCH DEPTH WALL HOOD WITH BLOWER (30"/36"/48") models: HPWB30FS, HPWB36FS, HPWB48FS PROFESSIONAL HPWB30FS – 30-Inch HPWB36FS – 36-Inch HPWB48FS – 48-Inch SPECIFICATIONS Available Hood Widths 30", 36", 48" Blower 30" – 600 CFM Blower Included 36" – 1200 CFM Blower Included 48"...
Page 18
6" and/or 12" duct covers are used to fill the space between the hood and ceiling. This Thermador Wall Hood can be mounted on a wall or suspended from a cabinet. The cabinet must be structurally joined to the wall studs to support the weight of this hood.
Page 19
Filters are highly efficient at capturing grease Powerfully quiet ventilation systems Extended capture area ensures removal of smoke and odor DESIgN Classic chiseled design matches Thermador’s Masterpiece® Series family of kitchen appliances Brushed stainless steel finish Welded, polished seams for a flawless design...
Page 20
Accessory 6" and/or 12" duct covers are used to fill the space between the hood and ceiling. Thermador Wall Hoods can be mounted on a wall or suspended from a cabinet. The cabinet must be structurally joined to the wall studs to support the weight of this hood.
Page 21
Filter systems are highly efficient at capturing grease Powerfully quiet ventilation systems Extended capture area ensures removal of smoke and odor DESIgN Classic chiseled design matches Thermador’s Masterpiece® Series family of kitchen appliances Brushed stainless steel finish Welded, polished seams for a flawless design...
Page 22
Accessory 6" and/or 12" duct covers are used to ll the space between the hood and ceiling. Thermador Wall Hoods can be mounted on a wall or suspended from a cabinet. The cabinet must be structurally joined to the wall studs to support the weight of this hood.
Page 23
MODEL HMCB42FS SHOWN WITH 36-INCH GAS COOKTOP SGSX365FS MODEL HMCB42FS SHOWN WITH 36-INCH GAS COOKTOP SGSX365FS...
Each model is adjustable to suit a range of ceiling heights and includes conveniences such as dishwasher safe, anodized lters and electronic 4-speed controls. Halogen lighting brilliantly illuminates your cooking space for excellent visibility. 1.800.735.4328 | THERMADOR.COM...
Page 25
(Except HMCB36FS, HMCB42FS) ELECTRICAL SPECIFICATIONS Be sure your Thermador Chimney Wall Hood is properly installed and grounded by a quali ed technician. Installation, electrical connections and grounding must comply with all applicable local codes.
Page 26
The speci ed CFM varies from locale to locale. Consult your HVAC professional for speci c requirements in your area. If using a 10" duct, Thermador recommends not exceeding 150 feet of duct. Transitions, elbows and wall or roof caps are all factors that will add more static pressure, therefore increasing your equivalent duct run.
Page 27
3 fan speeds plus 10 minute high-power operation mode Filters are highly ef cient at capturing grease Powerfully quiet ventilation systems DESIgN Classic chiseled design matches Thermador’s Masterpiece® Series family of kitchen appliances Brushed stainless steel nish Welded, polished seams for a flawless design...
Page 28
Thermador non-professional gas, electric, or induction cooktop, consult the appliance’s installation manual. Thermador Chimney Wall Hoods must be mounted on a wall. These hoods are designed to be used for vertical discharge. A blower must be purchased separately.
Page 29
3 fan speeds plus 10 minute high-power operation mode Filters are highly ef cient at capturing grease Powerfully quiet ventilation systems DESIgN Classic chiseled design matches Thermador’s Masterpiece® Series family of kitchen appliances Brushed stainless steel nish Welded, polished seams for a flawless design...
Page 30
Thermador non-professional gas, electric, or induction cooktop, consult the appliance's installation manual. Thermador Chimney Wall Hoods must be mounted on a wall. These hoods are designed to be used for vertical discharge. A 600 CFM integrated blower is included.
Page 31
VENTILATION PIVOT-LIFT gLASS CANOPY HOOD (36") Model: HgEW36FS MASTERPIECE HGEW36FS – 36-Inch SPECIFICATIONS Available Hood Widths 36" Blower 600 CFM Blower Included Duct Size at Discharge 6" Round Ducting Direction Vertical Ceiling Heights 8 ft. to 9 Dishwasher Safe Filters 1 Mesh Halogen Lighting ACCESSORIES...
Page 32
Thermador non-professional gas, electric, or induction cooktop, consult the appliance's installation manual. Thermador Chimney Wall Hoods must be mounted on a wall. This hood is designed to be used for vertical discharge. A 600 CFM integrated blower is included.
Page 33
Filters are highly ef cient at capturing grease Powerfully quiet ventilation systems Sound insulation mats make this hood barely audible DESIgN Classic chiseled design matches Thermador’s Masterpiece® Series family of kitchen appliances Brushed stainless steel nish Welded, polished seams for a flawless design...
Page 34
Thermador non-professional gas, electric, or induction cooktop, consult the appliance's installation manual. Thermador Chimney Wall Hoods must be mounted on a wall. This hood is designed to be used for vertical discharge. A 600 CFM integrated blower is included.
Page 35
MODEL HGSI42TS SHOWN WITH 36-INcH INDUcTION cOOKTOP cIS365GB AND DISHWASHER DWHD410GFM...
VENTILATION ISLAND HOODS Thermador Island Hoods put the nishing touches on your cooking system, with excellent overall ef ciency in drawing away smoke, moisture and heat. The adjustable chimney height is perfect over island cooktop or range installations. Dishwasher safe aluminum mesh lters make cleanup easy.
Page 37
(HNI42YS, HNI48YS, HNI54YS only) ELECTRICAL SPECIFICATIONS Be sure your Thermador Wall Hood is properly installed and grounded by a quali ed technician. Installation, electrical connections and grounding must comply with all applicable local codes.
Page 38
The speci ed CFM varies from locale to locale. Consult your HVAC professional for speci c requirements in your area. If using a 10" duct, Thermador recommends not exceeding 150 feet of duct. Transitions, elbows and wall or roof caps are all factors that will add more static pressure, therefore increasing your equivalent duct run.
Page 39
VENTILATION ISLAND HOOD (42"/48"/54") Models: HNI42YS, HNI48YS, HNI54YS PROFESSIONAL HNI42YS – 42-Inch HNI48YS – 48-Inch HNI54YS – 54-Inch SPECIFICATIONS Available Hood Widths 42", 48", 54" Blower Sold Separately— See Blower Options Table Duct Size at Discharge 8" Round Ducting Direction Vertical Ceiling Heights ft.
Page 40
INSTALLATION OPTIONS Thermador Professional Series Island Hoods may be installed above a Thermador Professional Cooktop or Range to create a convenient cooking center. Refer to the appropriate section for additional speci cations. Hood installation height above a cooktop can vary. To obtain the necessary installation height above a Thermador Cooktop or Range, consult the appliance's installation manual.
Page 41
VENTILATION ISLAND HOOD WITH BLOWER (42") Model: HgSI42TS MASTERPIECE HGSI42TS - 42-Inch SPECIFICATIONS Available Hood Widths 42" Blower 400 CFM Blower Included Duct Size at Discharge 6" Round Ducting Direction Vertical Ceiling Heights 8 ft. to 10 ft. Dishwasher Safe Filters Mesh Halogen Lighting PERFORMANCE...
Page 42
Hood installation height above a cooktop can vary. To obtain the necessary installation height above a Thermador Cooktop or Range, consult the appliance's installation manual. Thermador Island Hoods are suspended from the ceiling. These hoods are designed to be used for vertical discharge.
Page 43
48-Inch Pro Grand® ranGe Shown wIth cuStom VentIlatIon InSert...
VENTILATION CUSTOM INSERTS Use Thermador Custom Hood Inserts within custom hood applications to create a seamless design with wall or island applications. These inserts ef ciently and quietly remove odor and steam. Inserts are available for both professional and non-professional applications.
Page 45
21-inch (for 30-inch wide installations) and 29-inch (for 36-inch wide installations). ELECTRICAL SPECIFICATIONS Be sure your Thermador Custom Insert is properly installed and grounded by a quali ed technician. Installation, electrical connections and grounding must comply with all applicable local codes.
Page 46
The speci ed CFM varies from locale to locale. Consult your HVAC professional for speci c requirements in your area. If using a 10" duct, Thermador recommends not exceeding 150 feet of duct. Transitions, elbows and wall or roof caps are all factors that will add more static pressure, therefore increasing your equivalent duct run.
Page 47
VENTILATION CUSTOM INSERT (30"/36"/48") Models: VCI230DS, VCI236DS, VCI248DS PROFESSIONAL VCI230DS – 30-Inch VCI236DS – 36-Inch VCI248DS – 48-Inch Custom hood insert for use within wall or island custom hood applications SPECIFICATIONS Available Hood Widths 30", 36", 48" Blower Sold Separately— See Blower Options Table Duct Size at Discharge 10"...
Page 48
Thermador Professional Series Custom Hood Inserts may be installed above a Thermador Professional Cooktop or Range to create a convenient cooking center. Refer to the appropriate section for additional speci cations. Hood installation height above a cooktop can vary. Professional Rangetops and Ranges require that minimum distances be maintained from the cooking surface to combustible materials (i.e.
Page 49
VENTILATION CUSTOM INSERT WITH BLOWER (21"/29") Models: VCI21CS, VCI29CS MASTERPIECE VCI21CS – 21-Inch VCI29CS – 29-Inch Custom hood insert for use within custom hood applications SPECIFICATIONS Available Hood Widths 21", 29" Installation Width 21" Model – Up to 30" Wide 29"...
Page 50
Thermador Custom Hood Inserts within custom hood applications create a seamless design with wall or island applications. Thermador Masterpiece® Series Custom Hood Inserts may be installed above a Thermador non-professional gas, electric, or induction cooktop up to 36-inches wide to create a convenient cooking center.
Page 51
DOWNDRAFT MODEL UCVM36FS SHOWN WITH 36-INCH INDUCTION COOKTOP CIT365GM...
Page 52
VENTILATION DOWNDRAFT If you prefer a concealed look, choose a Thermador Downdraft Ventilation Unit, which offers space ef ciency when a hood is not preferred. A full face lter combines a lter with splatter shield in one easy-to-remove, dishwasher-safe element. Thermador invented the rst retractable downdraft, and was also the rst to introduce a recirculation option for downdrafts—making...
Page 53
These lters maximize grease capture without affecting airflow. Thermador Downdraft Hoods may be installed in a wall or island behind a Thermador non-professional gas, electric or induction cooktop to create a convenient cooking center. Refer to the appropriate section for additional speci cations.
Page 54
CFM varies from locale to locale. Consult your HVAC professional for speci c requirements in your area. If using a 10" duct, Thermador recommends not exceeding 150 feet of duct. Transitions, elbows and wall or roof caps are all factors that will add more static pressure, therefore increasing your equivalent duct run.
Page 55
Toe kick/socket can be vented in any direction Mounts to base of cabinet; recesses into toe kick To be used only with Thermador downdraft and integrated blower repLacement cHarcoaL fILterS Sold Separately as a Service Item (For use with Recirculation Module)
Page 56
INSTALLATION OPTIONS The Thermador Downdraft Hood System is available in 30-inch or 36-inch widths. It is intended for installation with Thermador non-professional gas, electric or induction cooktops only. A Recirculation Kit (RECIRC__FS) can be purchased separately and used in conjunction with the Integral Blower if ducting to the outside is not a viable option.