General Data - Trane Voyager 27½ to 50 Ton Installation, Operation And Maintenance Manual

27 1/2 to 50 ton - 60 hz 23 to 42 ton (81-148 kw) - 50 hz
Table of Contents

Advertisement

Table GD-1 — General Data — 27½ - 30 Tons
Cooling Performance
1
Nominal Gross Capacity
Natural Gas Heat
2
Heating Input (BTUH)
First Stage
Heating Output (BTUH)
First Stage
Steady State Efficiency (%)
3
No. Burners
No. Stages
Gas Supply Pressure (in. w.c.)
Natural or LP (minimum/maximum)
Gas Connection Pipe Size (in.)
Electric Heat
KW Range
5
Capacity Steps:
Compressor
Number/Type
Size (Nominal)
Unit Capacity Steps (%)
Motor RPM
Outdoor Coil
Type
Tube Size (in.) OD
Face Area (sq. ft.)
Rows/Fins Per Inch
Indoor Coil — Type
Tube Size (in.) OD
Face Area (sq. ft.)
Rows/Fins Per Foot
Refrigerant Control
No. of Circuits
Drain Connection No./Size (in)
Type
Outdoor Fan Type
No. Used/Diameter
Drive Type/No. Speeds
CFM
No. Motors/HP/RPM
Indoor Fan Type
No. Used
Diameter/Width (in)
Drive Type/No. Speeds
No. Motors/HP
Motor RPM
Motor Frame Size
Exhaust Fan Type
No. Used/Diameter (in)
Drive Type/No. Speeds/Motors
Motor HP/RPM
Motor Frame Size
Filters — Type Furnished
No./ Recommended Size (in)
6
Refrigerant Charge (Std./Hi Eff Cond Coil) (Lbs of R-22)
Minimum Outside Air T emperature
For Mechanical Cooling
Notes:
1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. Rated and tested in
accordance with the Unitary Large Equipment certification program, which is based on ARI Standard 340/360-93.
2. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards.
Ratings shown are for elevations up to 4,500 feet.
3. Steady State Efficiency is rated in accordance with DOE test procedures.
4. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
5. Maximum KW @ 208V = 41, @ 240V = 54. For Electric heat KW range per specific voltage, see table PD-10.
6. Filter dimensions listed are nominal. For actual filter and rack sizes see the Unit Installation, Operation, Maintenance Guide.
RT -PRC007-EN

General Data

27½ Ton
329,000
Low
350,000
600,000
250,000
425,000
283,500
486,000
202,500
344,500
81.00
1
2
2.5/14.0
2.5/14.0
3
/
4
27-90
5
2
2/Scroll
10/15
100/40
3450
Standard Efficiency
High Efficiency
Lanced
Lanced
3
/
8
51.33
2/16
Hi-Performance
1
/
2
31.67
2/180
TXV
1
1/1.25
PVC
Propeller
3/28.00
Direct/1
24,800
3/1.10/1125
FC
1
22.38/22.00
Belt/1
1/7 .50/10.00
1760
213/215T
Propeller
2/26.00
Direct/2/2
1.0/1075
48
Throwaway
16/16 x 20 x 2
4
(Std) 46.0/(High) 58.0
0 F
60 Hz
High
Low
350,000
250,000
283,500
202,500
81.00
81.00
2
1
2
2
2.5/14.0
1
3
/
4
Standard Efficiency
Lanced
3
/
3
/
8
8
51.33
51.33
3/16
2/16
30 Ton
363,000
High
600,000
425,000
486,000
344,500
81.00
2
2
2.5/14.0
1
27-90
5
2
2/Scroll
15
100/50
3450
High Efficiency
Lanced
3
/
8
51.33
3/16
Hi-Performance
1
/
2
31.67
2/180
TXV
1
1/1.25
PVC
Propeller
3/28.00
Direct/1
24,800
3/1.10/1125
FC
1
22.38/22.00
Belt/1
1/7 .50/10.00
1760
213/215T
Propeller
2/26.00
Direct/2/2
1.0/1075
48
Throwaway
16/16 x 20 x 2
(Std.) 46.6/(High) 58.0
0 F
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents