Trane Voyager 27½ to 50 Ton Installation, Operation And Maintenance Manual page 21

27 1/2 to 50 ton - 60 hz 23 to 42 ton (81-148 kw) - 50 hz
Table of Contents

Advertisement

Table GD-3— General Data — 50 Ton
Cooling Performance
1
Nominal Gross Capacity
2
Natural Gas Heat
Heating Input (BTUH)
First Stage
Heating Output (BTUH)
First Stage
Steady State Efficiency (%)
3
No. Burners
No. Stages
Gas Supply Pressure (in. w.c.)
Natural or LP (minimum/maximum)
Gas Connection Pipe Size (in.)
Electric Heat
KW Range
5
Capacity Steps:
Compressor
Number/Type
Size (nominal)
Unit Capacity Steps (%)
Motor RPM
Outdoor Coil
Type
Tube Size (in.) OD
Face Area (sq. ft.)
Rows/Fins Per Inch
Indoor Coil — Type
Tube Size (in.) OD
Face Area (sq. ft.)
Rows/Fins Per Foot
Refrigerant Control
No. of Circuits
Drain Connection No./Size (in)
Type
Outdoor Fan — Type
No. Used/Diameter
Drive Type/No. Speeds
CFM
No. Motors/HP/RPM
Indoor Fan Type
No. Used
Diameter/Width (in)
Drive Type/No. Speeds
No. Motors/HP
Motor RPM
Motor Frame Size
Exhaust Fan Type
No. Used/Diameter (in)
Drive Type/No. Speeds/Motors
Motor HP/RPM
Motor Frame Size
Filters — Type Furnished
6
No./Recommended Size (in)
Refrigerant Charge (Std./Hi Eff Cond Coil) (Lbs of R-22)
Minimum Outside Air Temperature
For Mechanical Cooling
RT -PRC007-EN
General Data
50 Ton
616,000
Low
400,000
300,000
324,000
243,000
81.00
1
2
2.5/14.0
3
/
4
41-108
5
2
3/Scroll
14
100/67/33
3450
Standard Efficiency
Lanced
3
/
8
69.79
2/16
Hi-Performance
1
/
2
37 .50
4/164
TXV
2
1/1.25
PVC
Propeller
4/28.00
Direct/1
31,700
4/1.10/1125
FC
1
25.00/25.00
Belt/1
1/10.00/15.00/20.00
1760
215/254/256T
Propeller
2/26.00
Direct/2/2
1.0/1075
48
Throwaway
17/16 x 20 x 2
4
(Std.) 30.7/54.3 per circuit
(High) 36.0/72.0 per circuit
0 F
60 Hz
Table GD-4 — Economizer Outdoor Air
Damper Leakage (Of Rated Airflow)
High
Standard
800,000
Optional "Low Leak"
600,000
Note: Above data based on tests completed in
648,000
accordance with AMCA Standard 500.
486,000
81.00
2
2
2.5/14.0
1
High Efficiency
Lanced
3
/
8
75.00
3/16
Notes:
1. Cooling Performance is rated at 95 F ambient, 80 F
entering dry bulb, 67 F entering wet bulb. Gross
capacity does not include the effect of fan motor heat.
Rated and tested in accordance with the Unitary
Large Equipment certification program, which is
based on ARI Standard 340/360-93.
2. Heating Performance limit settings and rating data
were established and approved under laboratory test
conditions using American National Standards
Institute standards. Ratings shown are for elevations
up to 4,500 feet.
3. Steady State Efficiency is rated in accordance with
DOE test procedures.
4. Refrigerant charge is an approximate value. For a
more precise value, see unit nameplate and service
instructions.
5. Maximum KW @ 208V = 41, @ 240V = 54. For Electric
heat KW range per specific voltage, see table PD-10.
6. Filter dimensions listed are nominal. For actual filter
and rack sizes see the Unit Installation, Operation,
Maintenance Guide.
ΔP Across Dampers (In. WC)
0.5 (In.)
1.0 (In.)
1.5 %
2.5 %
0.5 %
1.0 %
21