Trane Voyager 27½ to 50 Ton Installation, Operation And Maintenance Manual page 24

27 1/2 to 50 ton - 60 hz 23 to 42 ton (81-148 kw) - 50 hz
Table of Contents

Advertisement

24
General Data
Table GD-7 – General Data – 43 Tons
Cooling Performance
1
Nominal Gross Capacity - Btu (kW)
System Power - kW
Compressor
Number/Type
Size (Nominal Tons)
Unit Capacity Steps (%)
Motor rpm
Natural Gas Heat
2
Heating Input - Btu (kW)
First Stage
Heating Output - Btu (kW)
First Stage
3
Steady State Efficiency(%)
No. Burners/No. Stages
Gas Connect Pipe Size - in. (mm)
Outdoor Coil
Type
Tube Size OD - in. (mm)
Face Area - sq ft (sq m)
Rows/Fins Per Inch
Indoor Coil - Type
Tube Size OD - in. (mm)
Face Area - sq ft (sq m)
Rows/Fins Per Foot
Refrigerant Control
PVC Drain Connect No./Size - in. (mm)
Outdoor Fan Type
No. Used
Diameter - in. (mm)
Drive Type/No. Speeds
cfm (L/s)
No. Motors (rpm)
Motor - hp (kW)
Indoor Fan T ype/No. Used
Diameter - in. (mm)
Width - in. (mm)
Drive Type
No. Speeds/No. Motors
Motor hp
Motor rpm/Frame Size
Filters - Type
Furnished/No.
Recommended Size - in. (mm)
Refrigerant Charge (Std./Hi Eff Cond Coil) (Lbs of R-22)
Factory Charge Circuit 1 - lb (kg)
4
Factory Charge Circuit 1 - lb (kg)
Notes:
1. Cooling Performance is rated at 95°F (35°C) ambient, 80°F (27°C) entering dry bulb, 67°F (19°C) entering wet bulb. Gross
capacity does not include the effect of fan motor heat.
2. Heating Performance Limit settings and ratings data were established and approved under laboratory test conditions
using American National Standards.
3. Steady State Efficiency is rated in accordance with DOE test procedures.
4. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
Table GD-8 – Economizer Outdoor Air Damper Leakage (Of Rated Airflow)
Standard
Optional "Low Leak"
Note: Above data based on tests completed in accordance with AMCA Standard 500.
50 Hz
TC/YC/TE*500 (42Tons)
520,000 (152)
50.9
3/Scroll
14/14/14
100/67/33
2875
Low
335,000 (98.2)
670,000 (196)
300,000 (87.9 kW)
600,000 (176 kW)
271,350 (79.5)
542,700 (159)
243,500 (71.4 kW)
486,000 (166 kW)
81
1/2
0.75 (19)
Standard Efficiency
High Efficiency
Lanced
Lanced
0.375 (10)
0.375 (10)
69.8 (6.5)
75.0 (7 .0)
2/16
Hi-Performance
0.500 (13)
37 .5 (3.5)
4/164
TXV
1/1.25 (1/32)
Propeller
4
28.0 (711)
Direct/1
26,200 (12,400)
4 (940)
0.75 (0.56)
FC/1
25.0 (635)
25.0 (635)
Belt
1/1
10.0 (7 .5 kW)
1460/215T
Throwaway
Yes/17
16x20x2 (406x508x51)
4
(Std.) 30.7 (13.6)/54.3 (24.6)
(High) 36.0 (16.3)/72.0 (32.7)
ΔP Across Dampers (In. wc) (Pa)
0.5 In. (124.5 Pa)
1.5%
0.5%
High
3/16
1.0 In. (249 Pa)
2.5%
1.0%
RT-PRC007-EN