MAINTENANCE ITEM
Verify the area is free from combustible materials. See clearances on
page 17.
Verify the combustion and ventilation air is not restricted.
Verify the flue and inlet pipes do not have any cracks or holes.
Verify burner flame.
Clean the blower compartment
Clean the burner.
Verify the condensate system is clean and leak free.
Clean the Filter
Winterization
The UltraSaver should be inspected and serviced annually by a qualified service person. This will ensure that the wall furnace is operating
safely and efficiently. Should you suspect any abnormal operation, contact a service person that has been trained to service this product.
Maintenance for the Homeowner
Removing the Front Panel
It may become necessary to remove the front panel of the appli-
ance to remove dropped or fallen objects.
Remove the front panel by lifting up then pulling out. Replace the
panel by reversing this step.
WARNING
FOR YOUR SAFETY, TURN OFF POWER TO APPLIANCE.
WARNING
Do not operate this appliance without the front panel.
Cleaning the Filter
The filter is located on the back of the wall furnace. To clean the
filter, first open the filter cover on the back of the wall furnace. See
Figure 60.
Page 38
MAINTENANCE & SERVICE
RECOMMENDED MAINTENANCE
Figure 60
FREQUENCY OF MAINTENANCE
MONTHLY BY HOME-
OWNER
X
X
X
Next, remove the filter from the wall furnace by lifting it up and out.
See Figure 61.
The filter may be rinsed with water or blown clean with compressed
air. Allow the filter to dry completely before reinstalling it.
ANNUALLY BY
SERVICE PERSON
X
X
X
X
X
X
X
X
As Needed (determined by
weather)