Empire Heating Systems PVS18(N,P)-1 Owner's Manual And Installation Instructions page 10

Ultrasaver 90 plus wall furnace
Table of Contents

Advertisement

Wall Furnace Operations Sequence
1.
When the main power switch is turned on, the red and green
control board LED's will begin to flash alternately. If using the
FRBTPL Remote accessory (page 15) the remote receiver
will search for the remote transmitter's signal. See Figures
10 and 11.
Page 10
OWNER'S MANUAL
Figure 10
Figure 11
Each light will pulse four times then the wall furnace will
enter Remote mode. While in Remote mode, the green LED
will flash slowly and the display panel will shown a double
dash "- -". See Figure 12.
2.
When a call for heat is received, the wall furnace display
panel will illuminate and show the level. See Figure 13.
3.
Adjust level with the up and down adjustment buttons in Man-
ual Mode. If operating in Local mode, the heat level will adjust
automatically.
4.
The red and green control panel LED lights will begin to flash
alternately while the wall furnace performs a safety test. After
approximately 45 seconds the test will complete and the wall
furnace will prepare to ignite.
5.
After the safety test is complete, the ignitor will glow red and
the burner will light within approximately 30 seconds.
Notice: If the burner fails to light, the wall furnace will retry the
ignition sequence three times then enter lock-out mode if it fails
to light. See page 37 for the fault codes and their meanings.
6.
After the burner lights, the flame icon on the display panel will
appear and the wall furnace will automatically adjust to the
heat level shown on the display. The wall furnace will always
ignite on Level 5 (High) prior to adjusting to the heat level
shown on the display panel. See Figure 14.
Figure 12
Figure 13
Figure 14
32084-1-0713

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pvs35(n,p)-1Pvs18n-1Pvs18p-1Pvs35n-1Pvs35p-1

Table of Contents