Hood Exhaust - GE JVM1600 Series Installation Instructions Manual

Cooktop oven
Table of Contents

Advertisement

Installation
Instructions
HOOD EXHAUST
NOTE: Read these next two pages only if you plml to vent your exhaust to the
outside. If you plan to recirculate the air back into the room, proceed to page 6.
OUTSIDE
TOP EXHAUST
(EXAMPLE
ONLY)
The
following
chart
describes
an
example
ot one
possible
ductwork
instnllation.
DUCT PIECES
EQUIVALENT
NUMBER
LENGTH
x
USED
RoofCap
24 Ft.
x
12 Ft.Straight Duct
12 Ft.
x
(6" Round)
-_
Rectangular-to-Round
5 Ft.
x
TransitionAdaptor s
Equivalent l engthsof duct piecesare basedon actualtests and
reflect requirements for goodventingperformance with anyvent hood.
(1)
(1)
(1)
Total
Length
EQUWALENT
LENGTH
24 Ft.
12 Ft.
5 Ft.
41 Ft.
*IMPORTANT:
If a rectangula_to-rotmd
transition
adaptor
is used,
the
bottom
corners
of the
damper
will
haxe
to be
cut
to fit, using
the
tin
snips,
in order
to allow
free
moxement
of the
damper.
OUTSIDE
BACK EXHAUST
(EXAMPLE
ONLY)
The
following
chart
describes
an
example
ot one
possible
ductwork
installation.
EQUIVALENT
NUMBER
EQUIVALENT
DUCT PIECES
LENGTH*
x
USED
--
LENGTH
_Wall
Cap
40 Ft.
x
(1)
40 Ft.
3 Ft.StraightDuct
3 Ft.
x
(1)
3 Ft.
3W' x 10" Rectangular)
(_
90° Elbow
10 Ft.
x
(2)
20 Ft.
Equivalent l engthsof duct piecesare basedon actualtests and
reflect requirements for goodventing performance with anyvent hood.
Total Length
=
63 Ft.
NOTE:
For back
exhaust,
care
should
be
taken
to align
exhaust
with
space
between
studs,
or wall
should
be prepared
at the
time
it is constructed
by leaving
enough
space
between
the
wall
studs
to accommodate
exhaust.
4

Advertisement

Table of Contents
loading

Table of Contents