9.14.

REGULATORY INFORMATION

The Garrett Magnascanner PD 6500 PD meets or exceeds all of the requirements for
the 1991 Federal Aviation Administration (FAA) airport applications and specifications,
as well as the requirements of the National Institute of Law Enforcement and Criminal
Justice (NILECJ) standard # 0601.00, security levels 1–5. Conforms to the new Euro-
pean Electromagnetic Compatibility Directive, 89/336/EE; EN 55011, Group 2, Class B;
EN 50082-1.
Programs have been specifically designed to meet the FAA's three-gun test and the
Undetectable Firearm Act of 1991. The unit also complies with IEC standards for Safety
Requirements for Electronic Measuring Apparatus and meets eye safety requirements
of the AEL Class 1LED product CENELEC EN60825-1.
9.15.
INFRARED ANALYSIS
The performance of the Magnascanner PD 6500 is improved by an optional infrared
sensor that:
minimizes the effects of noise and other external influences by limiting the detection
capabilities to only those individuals and objects that are passing through the
detector;
greatly reduces the occurence of nuisance alarms by inhibiting alarm activity without
a person in the archway. In circumstances where large metal objects, such as
luggage or supply carts and x-ray equipment, pass by or are located near the unit,
the sensor automatically inhibits the alarm;
generates a traffic count of the number of persons passing through the detector.
9.16.
INTERFERENCE REJECTION
100% sensor coil Faraday shielding; special built-in circuitry by Garrett to suppress
noise and ignore x-ray monitor horizontal sync. Coil design and circuitry reduces physi-
cal interference. RFI-EMI filters provide attenuation from 10 MHz to 1000 MHz.
9.17.
MASKING
Unique microprocessor programming helps lessen the likelihood of dissimilar metal
objects canceling one another and evading detection.
9.18.
SYNCHRONIZATION
Multiple channels permit several Magnascanners to operate simultaneously and in
close proximity to one another.
9.19.

ELECTRICAL REQUIREMENTS

Fully automatic 100 to 240 VAC: 2 amps maximum; 50/60 Hertz, power: 55 watts maxi-
mum; no rewiring, switching or adjustments required. Power supply meets UL, CSA,
TUV and VDE standards. Also complies with IEC standards for Safety Requirements
for Electronic Measuring Apparatus and the Federal Communications Commission
Class B standards for noise emission from commercial electrical equipment.