4.

SYSTEM INFORMATION

4.1.
OPERATING INFORMATION
When you press the OPERATE touchpad for the first time, the READY light appears
and the LCD displays the message, GARRETT SECURITY. Press OPERATE again to
display the following information, in sequence:
LCD MESSAGE
1. S/N ########*
2. VERSION #.##
3. 60 or 50 Hz
4. SYNC MASTER or SLAVE
5. CHANNEL 1,2, or 3
6. PROG: XXXXXXXX
7. BASE SENSE: ###
8. SELF TEST...
9. BATT POWER XX%
10. SELF TEST OK
11. OPERATE
4.2.
SELF TEST
Should the self test reveal a problem a "failure" message will appear (e.g., SYNC FAIL).
(Refer to Table 4-1 for a list of possible failures and remedies.)
4.2.1.
CRITICAL FAILURES AND NON-CRITICAL FAILURES
Failures are classified as either "critical" or "non critical". A critical failure prevents the
PD 6500 from operating and must be corrected immediately. When a critical failure
occurs, the audio alarm sounds, the overhead display begins flashing and the mes-
sage, SYSTEM FAILURE, appears on the LCD.
A non-critical failure does not prevent the PD 6500 from operating; however, it should
be corrected as soon as possible.
CRITICAL FAILURES
• TX A or B FAIL
• POWER MOD FAIL
• RX A or B BOARD FAIL
• RX A or B ZN # PK FAIL
• CABLE MISCONNECT
©2000 GARRETT METAL DETECTORS, INC.
6/19/00
MAGNASCANNER PD 6500
OWNER'S MANUAL
software version
synchronization
base sensitivity setting
self test in progress
strength of battery when in use
self test reveals no problems
resume operate mode
NON-CRITICAL FAILURES
• NO SLAVE OUTPUT
• SLAVE SYNC
• AC SYNC or SYNC FAIL
• RX or TX OPTIC FAIL
• RX A or B ZN # BAL FAIL
11
DEFINITION
serial number
line frequency
channel status
program type
PN 1531100