5.

INSTALLATION ADJUSTMENTS

The Installation Adjustments mode enables the installer to make intial adjustments to
the PD 6500 and ensure it is functioning properly and free from interference. To access
this mode, press the ACCESS touchpad and enter the factory code: 5678. The
adjustable functions are displayed as follows, along with an underlined sample mes-
sage in parentheses:
Press ACCESS to scroll through the menu selections.
5.1.
LANGUAGE
The LCD provides prompts in several languages; select one using the + or – touchpads
Press ACCESS for the next adjustment or OPERATE to resume normal operation.
5.2.
RX BALANCE
RX balance refers to the balance level of the receiving antennas. Any number less than
50 is acceptable. A number greater than 50 will elicit the message, RX BAL #, and the
pinpoint lights within the problem zone will illuminate. Should this occur, ensure that
there is no large metal object adjacent to the PD 6500. Then, ensure that the balance
number has fallen below 50 and the corresponding pinpoint lights are off.
Press ACCESS for the next adjustment or OPERATE to resume normal operation.
5.3.
PACING LIGHTS
Pacing lights located on the side panels of the entrance side indicate whether or not a
patron may enter the walk-through. The green lights indicate walk and the red lights
indicate wait. Use the + or – touchpads to turn the pacing lights on or off.
Press ACCESS for the next adjustment or OPERATE to resume normal operation.
5.4.
ZN (ZONE) LIGHTS
This function establishes the duration that the pinpoint lights remain illuminated. Using
the + or – touchpads, select one of the following options: ZONE LIGHT: OFF; ZONE
LIGHT: 2 SEC; ZONE LIGHT: 3 SEC; or ZONE LIGHT: 4 SEC.
Press ACCESS for the next adjustment or OPERATE to resume normal operation.
5.5
ZONE SENSITIVITY
Adjusting the sensitivity of the six horizontal zones helps establish an optimal detection
field. Each zone adjustment is based on a percentage of the base sensitivity. The top to
bottom horizontal zones and their corresponding pinpoint lights are referred to as zones
one to six.
©2000 GARRETT METAL DETECTORS, INC.
6/19/00
MAGNASCANNER PD 6500
OWNER'S MANUAL
(LANGUAGE ENGLISH)
(
RX BAL OK 10)
(PACE LIGHTS ON)
(ZONE LIGHT: 2 SEC)
13
PN 1531100