Installation procedure
Install the hoisting screw
Use M8 or M10 hoisting screw (4, prepare on site) (When the height of hoisting
screw is more than 0.9m, you must use M10), their gaps refer to the dimension
of air conditioner, according to the original structure and the following method
to install.
wood structure
Put up the frame wood on the beam and mount the hoisting screws.
New cement panel
Use embedded parts and foot screw, etc to mount.
(Knife type embedded part)
Original cement panel
Use the in hole hinge, in hole
plug or in hole screw.
Steel structure
Directly use angle steel or new angle
steel for support.
Suspending of indoor unit
Fix the cap of hoisting screw on and suspend them on the T groove
of the hoisting part of the unit.
Use gradienter to keep the level degree of the unit within 5mm.
20
Frame wood
Beam
Hoisting screw
(Louver type embedded part)
(hoisting foot screw for connection pipe)

Install indoor unit

Iron
Foot screw
Suspending bolt
Hoisting screw
Angle steel for support