Install Indoor Unit - Haier 10571570 Operation Manual

Two by one room air conditioner
Table of Contents

Advertisement

Installation procedure
The indoor side drain hose and the parts connected with indoor unit should be
thermal insulated. Improper thermal insulation may cause dew-forming
phenomenon.
The drain hose should be as short as possible. The droop slant degree at least
should be 1/100 to avoid forming of gas bag.
If cannot make the drain hose have an enough slant degree, a drainage
enhancing hose should be equipped.
In order not to let the drain hose bend, a 1~1.5m distance should be kept
between suspending frame.
Droop slant degree over
1/100 Support frame
Thermal insulation material
(customer self-provided)
Thermal insulation treatment:
Use thermal insulation material, as figure shown, to bind
the hose and the hose buckle to the bottom of the indoor
unit without any gaps.
Hose
The hose can be used to adjust the radius and angle of stiff PVC pipe.
*Directly stretch the hose to perform work, do not make it deform.
*The soft end of the hose must be fixed by the hose buckle.
Please use the hose in the level part.
*
Radius adjustment
(Max 20mm)
<The attentive matters of drainage enhancing pipe>
The installation height of the drainage enhancing pipe should be less than 530mm.
The drainage enhancing pipe should be vertical to the unit and no more than 300mm away
from the unit.
Within 300mm
Drain hose
(accessory)
Wire clamp (accessory)
Instruction)
*The slant of the accessory drain hose should be within 75mm to make the drain faucet not
bear too much excessive external force.
If many drain hoses join together, please install according to the following procedure.
*
The specification of the chosen joined drain hoses should be applicable to the operation capacity of the unit.
1m*1.5m
***
*
45* bend
Hoisting foot
1-1.5m
Drainage enhancing pipe
S-shaped bend
Accessorial thermal
insulation material Thermal insulation material
(Max)
Drain hose
(accessory)
T-joint joined drain hose

Install indoor unit

As large as possible (about 10cm)
VP30
Droop slant degree over
1/100 Support frame
Hose buckle
Hose
Stiff PVC pipe
Hose buckle
Hose
Indoor unit
Hose
27