Haier AB072FDAHA Instruction Manual

Mrv intelligent network indoor air-conditioner
Hide thumbs Also See for AB072FDAHA:

Advertisement

MRV Intelligent Network Indoor Air-conditioner
Four way cassette type
AB092FEAIA AB092FEBIA
AB142FEAIA AB142FEBIA
AB182FEAIA AB182FEBIA
AB282FEAIA AB282FEBIA
AB362FEAIA AB362FEBIA
TWO way cassette type
AB072FDAHA AB072FDBHA
AB122FDAHA AB122FDBHA
AB162FDAHA AB162FDBHA
AB242FDAHA AB242FDBHA
Convertible Type
AC092FEAHA AC092FEBHA
AC122FEAHA AC122FEBHA
AC162FEAHA AC162FEBHA
AC182FEAHA AC182FEBHA
Duct Type
AD182FIAHA AD182FIBHA
AD282FIAHA AD282FIBHA
AD362FIAHA AD362FIBHA
Split Type
AS072FAAHA AS072FABHA
AS092FAAHA AS092FABHA
AS122FAAHA AS122FABHA
Ceiling concealed type
AE072FEAHA AE072FEBHA
AE092FEAHA AE092FEBHA
AE142FEAHA AE142FEBHA
AE182FEAHA AE182FEBHA
No. 0010570352
B
Please read this instruction manual before using the air conditioner
Please keep this manual carefully and safely.
AB122FEAIA AB122FEBIA
AB162FEAIA AB162FEBIA
AB242FEAIA AB242FEBIA
AB322FEAIA AB322FEBIA
AB452FEAIA AB452FEBIA
AB092FDAHA AB092FDBHA
AB142FDAHA AB142FDBHA
AB182FDAHA AB182FDBHA
AB282FDAHA AB282FDBHA
AC242FEAHA AC242FEBHA
AC282FEAHA AC282FEBHA
AC322FEAHA AC322FEBHA
AD242FIAHA AD242FIBHA
AD322FIAHA AD322FIBHA
AD452FIAHA AD452FIBHA
AS142FAAHA AS142FABHA
AS162FAAHA AS162FABHA
AS182FAAHA AS182FABHA
AE122FEAHA AE122FEBHA
AE162FEAHA AE162FEBHA
AE242FEAHA AE242FEBHA
AE242FLAHA AE242FLBHA

Advertisement

Table of Contents
loading

Summary of Contents for Haier AB072FDAHA

  • Page 1 Ceiling concealed type AE072FEAHA AE072FEBHA AE092FEAHA AE092FEBHA AE142FEAHA AE142FEBHA AE182FEAHA AE182FEBHA No. 0010570352 Please read this instruction manual before using the air conditioner Please keep this manual carefully and safely. AB122FEAIA AB122FEBIA AB162FEAIA AB162FEBIA AB242FEAIA AB242FEBIA AB322FEAIA AB322FEBIA AB452FEAIA AB452FEBIA...
  • Page 2 Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier. Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
  • Page 3: Specifications

    All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner. Do not damage any parts of the air conditioner that carry refrigerant by...
  • Page 4: Important Points Of Safety

    Important Points of Safety The following four important points of safety and suggestions should be paid great attention: Comply with the following important points of safety. Put these important points of attention and suggestions nearby and convenient for reference in need. Hand over this instruction manual to new user if you resell this machine.
  • Page 5 Important Points of Safety Avoid your body being blown directly by cold wind for long period, otherwise your health may be affected. When you have to disassemble and reinstall the machine, entrust it to after service. Improper installation may cause fire hazard, electric shock or damage of machine.
  • Page 6 Important Points of Safety Ensure ventilation of the room if the machine is used with burning facilities. Deficient ventilation can cause oxygen shortage. Check whether installation bench of the machine is damaged after a long period of use. Machine on damaged bench may fall down and cause human injury or other damage.
  • Page 7: Operation Features

    Operation Features Confirmation before running Check whether earthing wire is broken or falls off. Check whether air filter was omitted. Switch on power supply of the outdoor unit 12 hours in priority to entrust. Heat ability During heating program, the machine adopts heat pump mode to release heat indoors with that absorbed from outdoors. Therefore its heating ability reduces when outdoor temperature descends.
  • Page 8 Important Points of Use Donít turn on or turn off the machine with manual power switch Donít disconnect the manual power switch during usage of remote controller, operate with on/off button on the controller. disconnect! Turn on power supply of the outdoor unit 12 hours in priority to running.
  • Page 9: Name Of Each Part

    Name of Each Part Four way cassette type (AB182,242,282,322,362,452FEAIA) (AB182,242,282,322,362,452FEBIA) (AB092,122,142,162FEAIA) (AB092,122,142,162FEBIA) About Lou function Press " lou " button on the remote controller when necessary. If the controller keeps on showing louver and air guarding plate run automatically, it means this type has automatic swing function. If the control- ler shows louverr and manual at the same time and two signs disappear after several seconds, it means this type has no automatic swing function.
  • Page 10 Name of Each Part Convertible type Air guard- ing plate outlet (AC092,122,142,162FEAHA) (AC092,122,142,162FEBHA) Duct type Air Duct Inlet Air guarding plate Outlet Air filter Air filter Inlet Inlet (AC182,242,282FEAHA) (AC182,242,282FEBHA) Air filter Removing dust and dirt Outlet Air Duct Drainage hose...
  • Page 11 Name of Each Part Split type Intake grill Inlet Air filter Inlet Air guarding plate (adjusting wind direction up and down) Air direction lourer (adjusting wind direction right and left) Ceiling concealed type electric box outlet AE242FLAHA AE242FLBHA Air guarding plate Air direction lower (internal) (AS072,092,122,142FAAHA) (AS072,092,122,142FABHA)
  • Page 12: Operation Guide

    Operation Guide Display All content that can be shown on the display of remote controller are listed here to describe in details. In practical use, only content selected can be shown. Switch over of fan speed Showing fan speed mode selected Indoor unit Display of FAN Duct type...
  • Page 13 Operation Guide Operation MODE button Setting desired operation mode. TIMER button Setting time or continuous running mode. In time running mode, time power-on and power-off can be set. Running indicator It flashes after power is switched on or reenergized after power failure. During normal running, it stops flashing and lights.
  • Page 15 Operation Guide 2. Press ìFAN î button to select fan speed. The display changes in the following sequence at each press on the button. Mode 3. Press ìTEMPî button to select desired temperature. TEMP The display changes in the above sequence at each press on the button.
  • Page 16: Timer Operation

    Operation Guide TIMER operation Remaining time is displayed during time operation with unit of 1 minute. Time setting ranges from 10 minutes to 60 hours and is set with unit of 10 minutes. Time setting changes 10 minutes with each press of the button and changes with unit of hour if the press is hold on.
  • Page 17 Operation Guide Often clean air filter Blocked meshes of air filter can reduce heating and cooling effect of the air-conditioner. Close doors and windows in time Pay attention to avoid cool or hot wind spread out to outdoors. Avoid overcooling and overheating Avoid cool wind blowing your body directly for long period to prevent catching a cold and affecting your health.
  • Page 18 Adjustment of Wind Directions To enhance heating and cooling effect, angle of air guarding plate should be set for heat operation and cool operation respectively. As a characteristic of air, the cold stays below while the hot on the top. Air guarding plate should be in horizontal status during cooling program.
  • Page 19: Convertible Type

    Adjustment of Wind Directions Convertible Type In cool operation Adopt horizontal blowing to let cool air fulfill the whole room. Adjustment of wind directions to the left and right (AC092,122,142,162FEAHA * AC092,122,142,162FEBHA) have functions of auto adjustment) Adjust vertical swing leaf on inside of wind board to desired direc- tion to let blowing direction changes form the left to right.
  • Page 20: Maintenance

    Maintenance SHUT DOWN manual power switch before maintenance. Daily cleaning Cleaning of air filter REMOTE CONTROLLER MODE CENTRAL FAN ONLY AUTO OPERATION COOL HIGH MODE STANDBY PREHEAT HEAT DEFROST FILTER CHECK TEMP LOUVER DEMAND MANUAL UNIT TEMP TIMER CONT.OFF ON ADDRESS TEMER CHECK FILTER...
  • Page 21: Daily Cleaning

    Maintenance Slide ìhandle knobî on inlet panel to arrow direction. Open it down and turn control lever, then pull the air filter screen out. Use different cleaning method according to type of air filter screen installed. Consult after service for details. Daily cleaning Cleaning of air-conditioner and remote controller Wipe with dry and soft cloth.
  • Page 22: Troubleshooting

    Trouble Shooting Check the following before entrusting any after service. Presentation Sound of flowing water "click" sounds Blowing with smell Running indicator flashes Displays shows ìstand byî Sounds, white vapor or cool air during stopping of indoor unit Clickî sound while switch- ing on power of the machine The machine runs or stops automatically...

Table of Contents