ResMed Positive AirwAy Pressure Device S8 Series II User Manual

ResMed Positive AirwAy Pressure Device S8 Series II User Manual

S8 series ii positive airway pressure devices
Hide thumbs Also See for Positive AirwAy Pressure Device S8 Series II:

Advertisement

S8 Series II
S8 AutoSet Spirit™ II
S8 AutoScore™ II
POSITIVE AIRWAY PRESSURE DEVICES
User Guide
English
ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia
ResMed Corp (US Designated Agent) 14040 Danielson Street Poway CA 92064-6857 USA
ResMed (UK) Ltd (EU Authorized Representative) 96 Milton Park Abingdon Oxfordshire OX14 4RY UK
ResMed Offices Australia, Austria, Belgium, Brazil, China, Finland, France, Germany, Greece, Hong Kong, India, Ireland, Italy, Japan, Malaysia, Mexico,
Netherlands, New Zealand, Norway, Portugal, Singapore, South Africa, Spain, Sweden, Switzerland, UK, USA (see www.resmed.com for contact details).
Protected by patents: AU 691200, AU 697652, AU 709279, AU 724589, AU 730844, AU 736723, AU 750095, AU 750761, AU 764761, AU 779327, AU
2002231456, CN 02804930.6, EP 0651971, EP 0661071, EP 0920845, EP 0934723, EP 1028769, EP 1126893, EP 1502618, EP 1144036, JP 3580776, JP
3778797, NZ 504595, US 5199424, US 5245995, US 5522382, US 5704345, US 6029665, US 6138675, US 6240921, US 6363933, US 6367474, US 6425395,
US 6502572, US 6591834, US 6705315, US 6745768, US 6817361, US 6988498, US 7040317, US 7100608. Other patents pending.
Protected by design registrations: AU 302180, AU 302181, AU 302182, AU 302183, AU 302184, AU 302185, AU 302186, CN 200430121212.2, CN
200430121213.7, CN 200430121211.8, CN 200430121214.1, CN 200430121215.6, CN 200430121216.0, CN 200430121217.5, EU 269436, EU 815071, HK
0412901.9, JP 1257662, JP 1257663, JP 1266956, JP 1266957, JP 1267270, JP 1267271, NZ 405614, NZ 406923, NZ 406924, NZ 406925, NZ 406926, NZ
406927, NZ 406928, US D544598, US D553228, US D557406, US D557407, US D560795, US D561891, US D565160. Others pending.
S8, S8 AutoSet, S8 Elite and SmartStart are trademarks of ResMed Ltd and AutoSet and HumidAire are registered in U.S. Patent and Trademark Office.
© 2008 ResMed Ltd.
338575/2 08 10

Advertisement

Table of Contents
loading

Summary of Contents for ResMed Positive AirwAy Pressure Device S8 Series II

  • Page 1 406927, NZ 406928, US D544598, US D553228, US D557406, US D557407, US D560795, US D561891, US D565160. Others pending. S8, S8 AutoSet, S8 Elite and SmartStart are trademarks of ResMed Ltd and AutoSet and HumidAire are registered in U.S. Patent and Trademark Office.
  • Page 2: Table Of Contents

    Contents ..........1 Introduction Contraindications Adverse Effects...
  • Page 3: Introduction

    Introduction S8 AutoSet Spirit II The S8 AutoSet Spirit II self-adjusting sleep apnea system is indicated for the treatment of obstructive sleep apnoea (OSA) in adult patients. The S8 AutoSet Spirit II self- adjusting sleep apnoea system has two treatment modes: AutoSet and fixed-pressure CPAP.
  • Page 4: Parts Of The S8 Series Ii System

    A list of masks (and their settings) compatible with these devices can be found on www.resmed.com, on the Products page under Service and Support. Humidifiers A list of humidifiers compatible with ResMed devices can be found on www.resmed.com, on the Products page under Service and Support. ResScan Data Card The ResScan Data Card may be used with the S8 Series II either to help your clinician monitor your treatment or provide you with updates to your device settings.
  • Page 5: Using The S8 Series Ii

    Make sure the power cord and plug are in good condition and the • equipment is not damaged. Only ResMed air tubing should be used with the device. A different type • of air tubing may alter the pressure you actually receive, reducing the effectiveness of your treatment.
  • Page 6: How To Use The Control Panel

    How to Use the Control Panel Keypad Start/Stop key The control panel of the S8 Series II includes an LCD screen which displays the menus and treatment screens as well as a keypad for navigating through the menus and delivering treatment. The S8 Series II keypad has the following keys: Start/Stop Down...
  • Page 7: Using The Mask-Fitting Feature

    Press Press to apply. Using the Mask-fitting Feature You can use the S8 Series II mask-fitting feature to help you fit your mask properly. This feature delivers air pressure for a three-minute period, prior to starting treatment, during which you can check and adjust your mask fit to minimise leaks. Note: Make sure that the mask setting on the MASK screen is the same as the mask you are using.
  • Page 8: Stopping Treatment

    To start treatment, press Fit your mask as described in the mask user instructions. WARNING A mask should not be used unless the S8 Series II device is powered and operating properly. Stopping Treatment To stop treatment at any time, remove your mask and press If your clinician has enabled SmartStart, simply remove your mask and treatment will end.
  • Page 9: The Detailed Menu

    The Detailed Menu Your clinician may have enabled a detailed menu on your S8 Series II device. The figure below shows the detailed menu in each mode. To enter the detailed menu from the standby (RAMP or SETTLING) screen, press WELCOME CPAP >>>>>>...
  • Page 10: Messages On The S8 Series Ii Lcd

    Messages on the S8 Series II LCD Your clinician may have set your S8 Series II device to remind you about important events, such as when to replace your mask, when to insert your Data Card (if your device is Data Card enabled) and so on. The reminder message is displayed on the LCD and is visible if the device is not delivering therapy.
  • Page 11: Cleaning And Maintenance

    Remove the Data Card by gripping the end of the Data Card and pulling it out. Store the Data Card in its protective folder when not in use. Return the card in its protective folder to your clinician using a postal envelope. Updating Settings on your S8 device If your clinician has provided a Data Card with new device settings: With the device in standby (Ramp or Settling) mode, insert the Data Card into the...
  • Page 12: Replacing The Air Filter

    ResMed. To ensure that your device continues to provide optimum performance it is recommended that this product (S8 AutoSet Spirit II; S8 AutoScore II) be inspected by an authorised ResMed Service Centre five years from the date of purchase. Applicable ResMed warranty details are provided with the device at the time of original supply.
  • Page 13: Frequently Asked Questions

    CAUTION Do not attempt to open the S8 Series II case. There are no user • serviceable parts inside. Inspection and repair should only be performed by an authorised agent. • Under no circumstances should you attempt to service or repair the S8 Series II yourself.
  • Page 14: Troubleshooting

    Contact your clinician for details. Troubleshooting If there is a problem, try the following suggestions. If the problem cannot be solved, contact your equipment supplier or ResMed. Do not attempt to open the device. Problem/Possible Cause No display Power is not connected.
  • Page 15 Problem/Possible Cause Excessive leak. Displays error message: SYSTEM ERRxxxx Call Service! xxxx defines an error) Component failure. Displays error message: Check tube!! Key if done Air tubing is loose or blocked. The following message is displayed on the LCD after you try to update settings or copy data to the Data Card: Data Card is not inserted correctly.
  • Page 16: Technical Specifications

    (EMC) according to IEC60601-1-2, for residential, commercial, and light industry environments. The electromagnetic compatibility tables for these ResMed devices can be found on www.resmed.com, on the Products page under Service & Support. Click on the PDF file for your device. Two-layered, powder-bonded, polyester non-woven fiber...
  • Page 17: General Warnings And Cautions

    The S8 Series II should be used with masks (and connectors)* recommended • by ResMed, or by a physician or respiratory therapist. A mask should not be used unless the S8 Series II device is turned on and operating properly. The vent hole or holes associated with the mask should never be blocked.
  • Page 18 (6ºC) higher than the temperature of the room. Caution should be exercised if the room temperature is warmer than 90ºF (32ºC). When AC mains power (100–240V AC) is not available, always use a ResMed • DC-12 converter. (The DC-12 converter is available as an optional accessory. It is not supplied with all models.)
  • Page 19: Limited Warranty

    ResMed shall not be responsible for any incidental or consequential damages claimed to have occurred as a result of the sale, installation or use of any ResMed product. Some regions or states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
  • Page 21 Limited Warranty...

This manual is also suitable for:

S8 autoscore iiS8 autoset spirit ii

Table of Contents