Parameter Details; Peak Meter On/Off; Vu Meter Reference Level; Lighting Level Of Peak Over Indicator - Fostex FM-4 Owner's Manual

Portable mixer
Table of Contents

Advertisement

(3)
While the desired parameter to be edited is
flashing, you can select a desired value using
the [+] or [-] key .
In the following display example, both the left a
right peak meters are set to "
See "Parameter details" below for the available op-
tions of each parameter .
Flashing
(4)
After editing parameters, press the [EDIT] key long
enough to stop flashing .
(5)
Press the [EDIT] key to exit the status display mode .

Parameter details

Peak meter on/off

The meter display shows both VU and peak metering (de-
fault) .
The meter display shows only VU metering . The peak me-
tering is not shown .

VU meter reference level

The default value is "0 dB" . You can select between "0
dB" and "+7 dB" in 1 dB steps .
<Example>: If you set the reference level to "+5",
the level at 0 VU is +5 dB higher than the refer-
ence level .
<Memo>: It is recommended to change the refer-
ence level appropriately when an external audio de-
vice connected to the outputs of the unit has enough
headroom . Normally, set it to "0" .
<Memo>: If you set the reference level other than
"0", "+" is lit beside the "0" position of the VU meter,
showing that the 0 VU level is not the reference level .
Stereo VU meter
Left channel VU meter
" .
+
+


Lighting level of peak over indicator

The default is "+18 dB" . You can select between "0
dB" and "+18 dB" in 1 dB steps .
<Memo>: When peak level exceeds the lighting level,
"OVER" is lit on the stereo meter display, as pointed
by an arrow in the stereo meter display example below
left . On the meter status display, "0" is lit as pointed by
an arrow in the display example below right .
Lit
Lit
Stereo meter display
<Memo>: The details of the peak meter is as below .
Permitted Level
Alignment Level (AL)
AL
PML
Scale
Level
Level
@
-16 to +16
@+9dB
(Reference)

Internal battery selection

When you use alkaline batteries, select this op-
tion .
When you use nickel hydride batteries, select this
option .
<Note>: This setting allows the EMPTY indicator and the
alert for battery exchange work correctly according to the
battery type . When you operate the unit on internal battery
power, this item should be set correctly . Battery life depends
on the battery type, battery condition and usage environ-
ment . It is recommended to exchange batteries when the
EMPTY indicator starts flashing .
Alkaline
EMPTY indicator flashing
condition (approximately 30
Less than
minutes before batteries are
completely exhausted)
Less than
Alert for battery exchange*
Less than
Audio mute
* "Please change battery!" is shown as alert for battery exchange .
Meter status display
+13dBu (+9dB)
+4dBu (reference level)
Fall
Peak Hold
Attack
Time
Time
Time
1 . 7 sec/
0 . 1 msec .
2sec .
20dB
INT DC
EXT DC
Ni-MH
Less than
Less than
8 . 1 V
9 . 2 V
7 . 0 V
Less than
7 . 5 V
8 . 6 V
Less than
Less than
6 . 1 V
6 . 1 V
6 . 1 V
Lit

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents