Available languages

FAULT
LCD Digits
DESCRIPTION
Anomaly as parasit-
Desired flame
ic flame, APT failure
level is shown
or APS failure
Ignition lock-out
High water level
fault
Transducer fault
Pressure switch
fault
Overheat lock-out
Thermistor failure
Inadequate
Combustion Airflow
Thermistor temp too
high
29432-1-0512

TROUBLESHOOTING LCD FAULT CODES ON THE DISPLAY PANEL

Description
Yellow LED permanently OFF
Green and red LED blink slowly and simultaneously
Yellow LED permanently OFF
"A1"
Red LED permanently ON
Green LED performs 1 blink followed by a 1s pause
Yellow LED permanently OFF
"A2"
Red LED permanently ON
Green LED performs 2 blinks followed by a 1s pause
Yellow LED permanently OFF
"A3"
Red LED permanently ON
Green LED performs 2 blinks followed by a 1s pause
Yellow LED permanently OFF
"A4"
Red LED permanently ON
Green LED performs 4 blinks followed by a 1s pause
Yellow LED permanently OFF
Red LED permanently ON
"A5"
Green LED performs 5 blinks followed by a 1s pause
Yellow LED permanently OFF
"A6"
Red LED permanently ON
Green LED performs 6 blinks followed by a 1s pause
Yellow LED permanently OFF
"A7"
Red LED permanently ON
Green LED performs 7 blinks followed by a 3s pause
Yellow LED permanently OFF
Red LED permanently ON
"A0"
Green LED performs 1 blink followed by a 3s pause
ACTION
Turn off main power to the fire-
place for 30 minutes. If problem
persists, contact a qualified
service person
Check for gas presence.
Reset fireplace and retry ignition
sequence. If problem persists
contact a qualified service
person
Contact a qualified service
person
Check air pressure switch and
air pressure transducer hose
connections. Reset fireplace
and retry ignition. If problem
persists, contact a qualified
service person.
Check air pressure switch and
air pressure transducer hose
connections. Reset fireplace
and retry ignition. If problem
persists, contact a qualified
service person.
Allow fireplace to cool com-
pletely then reset fireplace.
If problem persists, contact a
qualified service person.
Contact a qualified service
person.
Contact a qualified service
person.
Allow fireplace to cool com-
pletely then reset fireplace.
If problem persists, contact a
qualified service person.