Figure 2
25 1/2"
(64.8 cm)
Rubber
Feet
may restrict air circulation. If installing the fireplace in a carpeted
area, place a one-piece, solid, flat surface under the fireplace insert.
Ensure that all four of the insert's feet rest securely on this surface.
Existing Fireplace Installation
1. Seal all drafts and vents with non-fibrous insulation materials to
prevent chimney debris from falling into the fireplace insert. Do not
install into an existing fireplace that is prone to leaks or dampness.
2. Cap the top of the chimney flue to prevent rain from entering.
3. Plan your electrical power supply (refer to NOTE 1).
4. The power cord can run along the front of the hearth to an outlet
near the fireplace.
! NOTE 1: A 15 Amp, 120 Volt circuit is required. A dedicated circuit
is preferred but not essential in all cases. A dedicated circuit will
be required if, after installation, the circuit breaker trips or fuse
blows on a regular basis when the heater is operating. Additional
appliances on the same circuit may exceed the current rating of the
circuit breaker.
30 1/4" (76.8 cm)
Air Circulation Areas
11 1/2"
(29.2 cm)