Electrical Service And Repair - Heatilator NBV3630I Owner's Manual

B-vent gas appliance
Hide thumbs Also See for NBV3630I:
Table of Contents

Advertisement

D. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to
disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
Optional SPST
Wall Switch
OR
Optional Remote
GRN*
WHT
* GRN wire only used with
optional wall switch
WSK-MLT-HTL
Figure 12.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram
28
Battery
Pack
- +
-
+
Limit
Switch
3V
Adaptor
BLK
BLK
BLU
RED
RED
Heatilator • Novus B-Vent Series • 4055-188 • Rev G • 03/09
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
Ignitor
Control
Box
To
ORG
Junction
Box
BLK
BRN
ORG
GRN
Valve
Flame
Sensor
Pilot Assembly
WHT

Hide quick links: