Framing And Clearances; Selecting Appliance Location - Heatilator NBV3630I Owner's Manual

B-vent gas appliance
Hide thumbs Also See for NBV3630I:
Table of Contents

Advertisement

5 5

Framing and Clearances

A. Selecting Appliance Location
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access. Due
to high temperatures, the appliance should be located out
of traffi c and away from furniture and draperies.
1/2 in. (13 mm) min.
appliance
to combustibles
B
Figure 5.1
Appliance Locations
18
B
Drywall
A
In addition to these framing dimensions, also reference the
following sections:
• Clearances and Mantel Projections (Sections 3.C. and 3.D.)
• Vent Clearances and Framing (Section 6)
Model
inches
NBV3630I
mm
inches
NBV3933I
mm
inches
NBV4236I
mm
inches
NBV4842I
mm
Heatilator • Novus B-Vent Series • 4055-188 • Rev G • 03/09
NOTICE: Illustrations refl ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
A
D
Alcove
Installation
A
C
A
B
C
36
33-1/2
19-5/8
914
851
498
39
35-1/2
19-5/8
991
902
498
42
37-5/8
19-5/8
1067
956
498
48
41-7/8
19-5/8
1219
1064
498
C
48 in.
(1219 mm)
max.
D
37
940
40
1016
43
1092
49
1245

Hide quick links: