5-Wire Thermostat
W
Y RC RH G
Wire
nuts
1
2
3
4
E2EB FURNACE Control Plug
(6-pin matrix)
2-Wire Thermostat
W
R
Wire
nuts
1
2
3
4
E2EB FURNACE Control Plug
(6-pin matrix)
INSTALLER: Do Not Discard These Instructions. After completing the installation,
return these instructions to the Homeowner's Package for owner-user's future
Complies with H.U.D. Manufactured Home Construction & Safety Standards.
St. Louis, MO
To A/C
5
6
Unstripped
Wires
5
6
Figure 28. E2EB Thermostat Connection
reference.
707716C
4-Wire Thermostat
W
Y
R
Wire
nuts
1
2
3
E2EB FURNACE Control Plug
(6-pin matrix)
Heat Pump Thermostat
G
R W
C
2
Wire
nuts
1
2
3
E2EB FURNACE Control Plug
(6-pin matrix)
707716C (Replaces 707716B)
Specifications and illustrations subject to change
without notice and without incurring obligations.
G
To A/C
4
5
6
E
O
Y
To
A/C
4
5
6
Printed in U.S.A. (01/00)