Download Print this page

Nordyne AireCare 707831C Installation Instructions

Electronic air filter for furnaces

Advertisement

Quick Links

AireCare
TM
Electronic
Air Filter
For M1 and E2 Series Furnaces
Congratulations
on your
installation
of an
AireCare
TMElectronic
Air Filter - the newest
and one of the most efficient
ways to reduce
indoor
air pollution
in the home.
Used
correctly,
it will help
protect
your
indoor
environment
from allergy
causing pollutants
such as pollen, plant spores,
lung damaging
particles
like tobacco
and cooking
smokes,
fungi, bacteria,
and some viruses.
iMPORTANT:
Read all instructions carefully
before
starting
the installation.
Specifica-
tions
or designs are subject
to change
or
discontinuance
without
notice and without
incurring obligations.
These
instructions
are primarily
intended
to
assist qualified individuals
experienced
in the
proper installation
of heating and/or air condi-
tioning appliances.
Some local codes require
licensed installation/service
personnel
for this
type of equipment.
WARNING:
improper
installation
may
damage
equipment,
create
a hazard,
and will
void thewarranty.
DO NOT CONNECT
TO 110 Volts
AC - the unit is designed
to operate
on 24 VAC.
/!X DANGER:
Shut
off
electrical
supply
to
the
furnace
at the household
breaker
box
to prevent
electrical
shock
and avoid
injury.
M1 AireCare
TM
Electronic
Air Filter
Installation
Instructions
Before starting this installation, make sure that
all electrical
power to the furnace
has been
disconnected.
The M1 AireCare
TM
Electronic Air Filter kit con-
sists of two brackets, four screws, a filter grille,
two protective edging strips, and the electronic
air filter with power cable. To install the kit, the
two brackets must be mounted onto the door of
the M1 furnace as shown in Figure 1.
Install
the Brackets
1.
install the protective
sheet metal edging
strips into the upper left louver of the M1
door (See Figure 1).
2.
Locate the bottom bracket (See Figure 1)
and remove the protective
tape from the
back.
3.
Place the bracket into the bottom louver of
the M1 door with the flange pointing to-
wards the top of the door.
Permanently
mount the bracket to the door using two of
the supplied screws.
4.
Locate the top bracket (See Figure 1) and
remove the protective tape from the back.
5.
Place the bracket into the top louver of the
M1 door with the flange pointing towards
the bottom of the door. Permanently mount
the bracket to the door using two of the
supplied screws.
Install the Filter
1.
Connectthe
electronicairfilterpowerwires
(24 VAC) to the red and gray low voltage
terminals (R and C). Run this wire through
the left side of the top louver of the M1 door.
Connect the power wire marked with white
stripe or dash to C, the other to R. Place the
door on the furnace and latch.
2.
Place the electronic air filter into the brack-
ets on the door by inserting it up into the top
bracket then allowing
it to drop into the
bottom bracket.
3.
Connect the electronic air filter power wire
jack into the filter. Power the furnace.
The
AireCare
TM
Electronic Air Filter is active if
the light on top of the electronic air filter is lit.
4.
Place the filter grille over the top bracket.
There are two tabs that attach the grille to
the top bracket.
The grille will now fit over
the bottom bracket and is held there by a
permanent
magnetic.

Advertisement

loading

Summary of Contents for Nordyne AireCare 707831C

  • Page 1 AireCare Electronic For M1 and E2 Series Furnaces Congratulations on your installation AireCare TMElectronic Air Filter - the newest and one of the most efficient ways to reduce indoor air pollution in the home. correctly, it will help protect environment from allergy causing pollutants such as pollen, plant spores,...
  • Page 2 AireCare Electronic Air Filter Grille Figure 1. M1 Bracket E2 AireCare Electronic installation Instructions (2-4 Ton A/C) Before starting this installation, make sure that all electrical power to the furnace disconnected. The E2 electronic air filter kit consists of one filter bracket, two screws, and the electronic air filter with power cable.
  • Page 3 E2 AireCare Electronic Installation Instructions (5 Ton A/C) Before starting this installation, make sure that all electrical power to the furnace disconnected. The 5 Ton E2 AireCare ElectronicAir consists of a through the wall grille and frame kit and the electronic air filter with power cable. Install Frame Cut a rough-in opening (20"...
  • Page 4 NORDYNE Normal maintenance MONTH to remove accumulated outside screens, and EVERY THREE TO SIX MONTHS to replace the glass fiber pads.

This manual is also suitable for:

M1 seriesE2 series