SPECIFICATIONS

BTU (Available)
Type of Gas
Ignition
Pressure Regulator Setting
Inlet Gas Pressure (Maximum)
Inlet Gas Pressure (Minimum)
Burners / Orifice nozzles
Thermostatic Control
Clearances: inches (mm)
Top
Sides
Floor (min. to top of carpet)
Fabric / flammable objects

PRECAUTIONS:

1. BF-10 LP and IR-10LP may be installed in a bed-
room, but not a bathroom, or any place where a
strong wind would shut down the appliance.
2. This heater needs outside ventilation air to run
properly. The Oxygen Depletion Sensor (ODS) safety
shutoff system shuts down the heater if not enough
fresh air is available. See Fresh Air for Combustion
and Ventilation, page 3.
3. Keep all air openings in heater clear, free of debris
or any blockage. This will insure that enough air for
proper combustion enters the heater.
4. If heater shuts off, do not relight until you provide
fresh, outside air. If heater keeps shutting off, it re-
quires servicing.
5. Turn off and let cool before servicing. Only a quali-
fied service person should service and repair heater.
6. Do not run heater:
• Where flammable liquids or vapors are used or stored
• During dusty conditions.
7. Before using furniture polish, wax, carpet cleaner or
similar products, turn heater off. If heated the vapors
from these products may create a white powder
residue within burner box or on adjacent walls or
furniture.
8. Do not use heater if any part has been underwater.
Immediately call a qualified service technician to in-
spect the room heater and to replace any part of the
control system and any gas control which has been
underwater.
9. Operating heater above elevations of 4,500 feet
could cause pilot/ODS to shutdown heater.
10.Always run heater with control knob in a locked posi-
tion. Never set control knob between locked posi-
tions. Poor combustion and higher levels of carbon
monoxide may result if control knob is left between
locked positions.
Unvented Liquid Propane Fired Room Heater
IR10 LP
10,000
LP-Gas Only
Piezo
10 Inches of Water
14 Inches of Water
11 Inches of Water
2
No
36" (915cm)
6" (152cm)
2" (51cm)
36" (915cm)
DANGER: Carbon monoxide poisoning may lead to
death.
Carbon Monoxide Poisoning:
Early signs of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If you have
these signs, the heater may not be working properly.
Get fresh air at once! Have heater serviced. Some
people are more affected by carbon monoxide than oth-
ers. These include pregnant women, persons with heart
or lung disease or anemia, those under the influence of
alcohol, and those at high altitudes.
Propane/LP Gas:
Propoane/LP gas is odorless. An odor making agent is
added to propane/LP gas. The odor helps you detect
a Propane/LP gas leak. However the odor added to
propane/LP gas may be present even though no odor
exists. Make certain you read and understand all warn-
ings. Keep this manual for reference. It is your guide to
safe and proper operation of this heater.
Product Features
3
Installation Instructions and Owner's Manual
BF10LP
10,000
LP-Gas Only
Piezo
10 Inches of Water
14 Inches of Water
11 Inches of Water
1
No
36" (915cm)
6" (152cm)
2" (51cm)
36" (915cm) 36" (915cm)
Burners
Grill
Front Panel
Figure 1
Control Knob
Heater
Cabinet