Specifications; Precautions - Mr. Heater HSVFRD10LP Operating Instructions And Owner's Manual

Unvented lp-gas fired room heater
Table of Contents

Advertisement

SPECIFICATIONS

MODEL
BTU (Available)
Type of Gas
Ignition
Pressure Regulator Setting
Inlet Gas Pressure (Maximum)
Inlet Gas Pressure (Minimum)
Burners / Orifi ce nozzles
Thermostatic Control
Top
Sides
Floor (min. to top of carpet)
Fabric / fl ammable objects
**Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater.**

PRECAUTIONS:

1. 10,000 BTU units may be installed in a bedroom, but
not a bathroom, or any place where a strong wind
would shut down the appliance.
2. This heater needs outside ventilation air to run
properly. The Oxygen Depletion Sensor (ODS) safety
shutoff system shuts down the heater if not enough
fresh air is available. See Fresh Air for Combustion
and Ventilation, page 4.
3. Keep all air openings in heater clear, free of debris
or any blockage. This will ensure that enough air
for proper combustion enters the heater.
4. If heater shuts off, do not relight until you provide
fresh, outside air. If heater keeps shutting off, it
requires servicing.
5. Turn off and let cool before servicing. Only a qualifi ed
service person should service and repair heater.
6. Do not run heater:
• Where fl ammable liquids or vapors are used or stored
• During dusty conditions.
7. Before using furniture polish, wax, carpet cleaner or
similar products, turn heater off. If heated, the
vapors from these products may create a white
powder residue within burner box or on adjacent
walls or furniture.
8. Do not use heater if any part has been underwater.
Immediately call a qualifi ed service technician to
inspect the room heater and to replace any part of
the control system and any gas control which has
been underwater.
9. Operating heater above elevations of 4,500 feet
could cause pilot/ODS to shutdown heater.
10.Always run heater with control knob in a locked
position. Never set control knob between locked
positions. Poor combustion and higher levels of
carbon monoxide may result if control knob is left
between locked positions.
Unvented Liquid Propane Fired Room Heater
HSVFRD10LP
10,000
LP-Gas Only
Piezo
10 Inches of Water
14 Inches of Water
11 Inches of Water
2
No
Clearances: inches (mm)
36" (915cm)
10" (254cm)
3" (76cm)
36" (915cm)
DANGER: Carbon monoxide poisoning may lead to
death.
Carbon Monoxide Poisoning:
Early signs of carbon monoxide poisoning resemble
the fl u, with headaches, dizziness, or nausea. If you
have these signs, the heater may not be working
properly. Get fresh air at once! Have heater serviced.
Some people are more affected by carbon monoxide
than others. These include pregnant women, persons
with heart or lung disease or anemia, those under the
infl uence of alcohol, and those at high altitudes.
Propane/LP Gas:
Propoane/LP gas is odorless. An odor making agent is
added to propane/LP gas. The odor helps you detect
a Propane/LP gas leak. Make certain you read and
understand all warnings. Keep this manual for
reference. It is your guide to safe and proper
operation of this heater.
Product Features
3
HSVFBF10LP
10,000
LP-Gas Only
Piezo
10 Inches of Water
14 Inches of Water
11 Inches of Water
1
No
36" (915cm)
10" (254cm)
3" (76cm)
36" (915cm) 36" (915cm)
Burners
Grill
Front Panel
Figure 1
Installation Instructions and Owner's Manual
Control Knob
Heater
Cabinet

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hsvfbf10lp

Table of Contents