SPECIFICATIONS

**Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater
MODEL
BTU (Available)
Type of Gas
Ignition
Pressure Regulator Setting
Inlet Gas Pressure (Maximum)
Inlet Gas Pressure (Minimum)
Electrical Rating /Blower
Thermostatic Control
Top
Sides
Floor (min to top of carpet) 3" (76cm)
Fabric / fl ammable objects

PRECAUTIONS:

1. 20,000 BTU or 30,000 BTU may not be installed
in a bedroom or bathroom, or any place where a
strong wind would shut down the appliance.
2. This heater needs outside ventilation air to run
properly. The Oxygen Depletion Sensor (ODS)
safety shutoff system shuts down the heater if not
enough fresh air is available. See Fresh Air for
Combustion and Ventilation, pages 5 through 6.
WARNING: An unvented heater having an input
of more than 10,000 Btu/hr (2 931W) shall not be
installed in a bedroom or bathroom.
3. Keep all air openings in heater clear, free of debris
or any blockage. This will insure that enough air for
proper combustion enters the heater.
4. If heater shuts off, do not relight until you provide
fresh, outside air. If heater keeps shutting off, it
requires servicing.
5. Turn off and unplug heater and let cool before
servicing. Only a qualifi ed service person should
service and repair heater.
6. Do not run heater:
Where fl ammable liquids or vapors are used or
stored
During dusty conditions.
7. Before using furniture polish, wax, carpet cleaner
or similar products, turn heater off. If heated the
vapors from these products may create a white
powder residue within burner box or on adjacent
walls or furniture.
8. Do not use heater if any part has been underwater.
Immediately call a qualifi ed service technician to
inspect the room heater and to replace any part of
MHVFRD20BT/
MHVFRD20T LP
18,000
LP-Gas Only
Battery ignitor (1-AA)
10 Inches of Water
14 Inches of Water
11 Inches of Water
120V, 60Hz , 1
Yes
Clearances: inches (mm)
36" (915cm)
10" (254cm)
36" (915cm)
Unvented LP-Gas Vent Free Room Heaters
MHVFRD30TB /
MHVFBF20TB /
MHVFRD30T LP
MHVFBF20T LP
30,000
20,000
LP-Gas Only
LP-Gas Only
Battery ignitor (1-AA)
Battery ignitor (1-AA)
10 Inches of Water
10 Inches of Water
14 Inches of Water
14 Inches of Water
11 Inches of Water
11 Inches of Water
120V, 60Hz , 1
120V, 60Hz , 1
Yes
Yes
36" (915cm)
36" (915cm)
10" (254cm)
10" (254cm)
3" (76cm)
3" (76cm)
36" (915cm)
36" (915cm)
the control system and any gas control which has
been underwater.
9. Operating heater above elevations of 4,500 feet
could cause pilot/ODS to shutdown heater.
10. Always run heater with control knob in a locked
position. Never set control knob between locked
positions. Poor combustion and higher levels of
carbon monoxide may result if control knob is left
between locked positions.
DANGER: Carbon monoxide poisoning may lead to
death.
Carbon Monoxide Poisoning:
Early signs of carbon monoxide poisoning resemble
the fl u, with headaches, dizziness, or nausea. If you
have these signs, the heater may not be working
properly. Get fresh air at once! Have heater serviced.
Some people are more affected by carbon monoxide
than others. These include pregnant women, persons
with heart or lung disease or anemia, those under the
infl uence of alcohol, and those at high altitudes.
Propane/LP Gas:
Propane/LP gas is odorless. An odor making agent is
added to propane/LP gas. The odor helps you detect
a Propane/LP gas leak. However the odor added to
propane/LP gas may be present even though no odor
exists. Make certain you read and understand all
warnings. Keep this manual for reference. It is your
guide to safe and proper operation of this heater.
Installation Instructions and Owner's Manual
3
.**
MHVFBF30TB /
MHVFBF30T LP
30,000
LP-Gas Only
Battery ignitor (1-AA)
10 Inches of Water
14 Inches of Water
11 Inches of Water
120V, 60Hz , 1
Yes
36" (915cm)
10" (254cm)
3" (76cm)
36" (915cm)