2.1 Deco Specifications

Fuel Type
Test Standards (safety)
Test Standard (emissions)
Heating capacity range*
Maximum heat output**
(EPA test fuel)
Maximum heat output**
(natural hardwood fuel)
Optimum efficiency
Test Standard (efficiency)
Approximate Burn Time
Shipping Weight
Firebox Volume
Maximum Log Length
Flue Outlet Diameter:
Baffle Material
* Combustion autonomy and heating capacity may vary subject to location in home,
chimney draft, chimney diameter, locality, heat loss factors, climate or fuels.
** The EPA test fuel is dimensional Douglas fir pieces stapled together into cribs with air
spaces between. We also test using the same procedure except using split hardwood
firewood to reflect real-world heat output. This stove is not intended to operate at its peak
heat output continuously.
*** East-west: through the door you see the sides of the logs; north-south: through the door
you see the ends of the logs
Cordwood
ULC S627, UL 737 and UL 1482
EPA Method 28 (40 CFR Part 60)
500 to 1700 sq. ft. (46,5 to 157,9 m
29 300 BTU/h (8,6 kW/h)
65 000 BTU/h (19,0 kW/h)
77 %
CSA B415.1-10
3 to 5 hours
330 lb (149,7 kg)
3
1,5 cu.ft. (0,044 m
)
22" east-west***
6" (150 mm) diameter (vertical)
Steel and firebrick
2
)