alarm. Should someone open the exit/entry
door, the alarm will sound immediately.
NOTE: When disarming the panel, exit/entry
delays will automatically be reinstated.
Panic Zone
The Panic Zone is always active, whether your
system is armed or not. To activate the Panic
Zone, simultaneously press the two keys [*]
and [#] on the keypad. The Panic Zone may be
programmed to activate an audible alarm, to
send a silent alarm to a central station
(optional), or both.
NOTE: The [*] and [#] buttons must be
pressed at the same time to activate the Panic
Zone. If the Panic Zone is activated, no zone
violation will be indicated at the keypad, but an
alarm condition will be recorded by Alarm
History (see Hold-Down Functions, Key [2]).