RUN/LOAD Switch (behind hinged front panel,
not shown). Used to load the user arm/disarm
codes. This switch is set to the LOAD position
when entering personal codes (refer to
Loading Personal Codes). The switch must
be returned to the RUN position after all codes
have been entered to resume alarm operation.
The system will not operate with the switch in
the LOAD position.
Hold-Down Functions
In addition to its regular functions, the keypad
provides a series of dual functions. Note that
these functions are accessed by holding down
the designated key for about 2 seconds, until a
beep sounds from the Mini-Sounder, and are
thus known as "Hold-Down" functions.
-
Key [1]
Test. This will momentarily sound
the bell or siren. A weak alarm may indicate
the need for battery replacement. Make this
test weekly.
-
Key (2]
Alarm History. This will flash the
red ARMED/MEMORY light to indicate all
alarm conditions that have occurred. While
holding down Key [2]. count the number of
flashes to determine the zone(s) violated. After
the system is rearmed, the previous alarm his-
tory will remain in alarm memory until
automatically reset by a new alarm condition.
Key [3] - STATUS Flashing Off/On. Hold
down Key [3] to stop the STATUS light flash-
ing. Repeat to turn STATUS flashing back on.
Key [4] - Instant Protection. This will cancel
the exit/entry delay periods when pressed
before arming. This feature is utilized to sound
an instant alarm on intrusion through the Exit/
Entry Zone(s). If used after arming, only the
entry delay will be cancelled. When selected,
the red ARMED/MEMORY light will flash
rapidly as a reminder that the system is armed
with instant protection. Exit/entry delay is
automatically reinstated on disarming.
Key [5] - Door Chime Off/On. If Zone 1 is
selected as the regular entry door, the Mini-
Sounder will beep upon entry while disarmed.
To enable the Door-Chime feature, hold down
Key [5] until it beeps.
-
Key [9]
Reset. This key is used to reset
Door Chime, reset a Day Zone, or bypass a
trouble on a zone designated as Priority Zone
With Bypass. See Priority Zone With Bypass
in the Glossary.
-
Key [S]
Display SHUNT. This will flash the
yellow SHUNT light to indicate the zone(s)
shunted. While holding down Key [S], count
the number of flashes to determine the zone(s)
shunted.
7

Advertisement

Table of Contents
loading