N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote User Manual

Electrical - All Models

The machine does not include a power cord, one
must be field supplied or the machine hard wired to
the electrical power supply.
The junction box for the power cord is on the back
panel. See the next page.
Refer to the dataplate on the machine for minimum
circuit ampacity and determine the proper wire size
for the application. The dataplate (on the back of
the cabinet) also includes the maximum fuse size.
Dimensions
Model
w" x d" x h"
N0422A-1
22 x 24 x 23
N0422W-1
same
F0522A-1
same
F0522W-1
same
N0622A-1
same
N0622W-1
same
N0622R-1
same
N0622A-32
same
N0622W-32
same
F0822A-1
same
F0822W-1
same
F0822R-1
same
F0822A-32
same
F0822W-32
same
N0922A-32
22 x 24 x 27
N0922W-32
same
N0922R-32
same
N0922A-3
same
N0922R-3
same
F1222A-32
same
F1222W-32
same
F1222R-32
same
F1222A-3
same
F1222W-3
same
F1222R-3
same
N1322A-32
same
N1322W-32
same
N1322R-32
same
F1522A-32
same
F1522W-32
same
Connect electrical power to wires inside the
junction box in the back of the cabinet. Use a strain
relief and connect a ground wire to the ground
screw.
Remote models power the condenser fan motor
from marked leads in the junction box.
Do not use an extension cord. Follow all local and
national codes.
Voltage
Condenser
Type
Volts/Hz/Phase
115/60/1
Air
111/60/1
Water
115/60/1
Air
115/60/1
Water
115/60/1
Air
115/60/1
Water
115/60/1
Remote
208-230/60/1
Air
208-230/60/1
Water
115/60/1
Air
115/60/1
Water
115/60/1
Remote
208-230/60/1
Air
208-230/60/1
Water
208-230/60/1
Air
208-230/60/1
Water
208-230/60/1
Remote
208-230/60/3
Air
208-230/60/3
Remote
208-230/60/1
Air
208-230/60/1
Water
208-230/60/1
Remote
208-230/60/3
Air
208-230/60/3
Water
208-230/60/3
Remote
208-230/60/1
Air
208-230/60/1
Water
208-230/60/1
Remote
208-230/60/1
Air
208-230/60/1
Water
November 2009
Page 8
Min Circ
Max Fuse Size or HACR
Ampacity
Type Circuit Breaker
15.2
14.4
15.2
14.4
18.3
16.7
19.4
9.8
8.9
18.3
16.7
19.4
9.8
8.9
12.5
11.3
12.3
13.0
12.8
12.5
11.3
12.3
13.0
11.8
12.8
19.1
17.9
18.9
19.1
17.9
20
20
20
20
25
25
25
15
15
25
25
25
15
15
15
15
15
15
15
15
15
15
15
15
15
30
30
30
30
30

Advertisement