Scotsman F0522 Installation And User Manual

Scotsman F0522 Installation And User Manual

Modular flaked & nugget ice machines

Advertisement

Installation and
User's Manual for
Modular Flaked & Nugget Ice Machines
Models F0522, F0822, F1222, F1522,
N0422, N0622, N0922 and N1322
Air Cooled, Water Cooled and Remote Air Cooled

Advertisement

Table of Contents
loading

Summary of Contents for Scotsman F0522

  • Page 1 Installation and User's Manual for Modular Flaked & Nugget Ice Machines Models F0522, F0822, F1222, F1522, N0422, N0622, N0922 and N1322 Air Cooled, Water Cooled and Remote Air Cooled...
  • Page 2: Table Of Contents

    Location: ..........Page 3 N0422, F0522, N0622, F0822, N0822 Cabinet Layout ..... Page 4 N0922, F1222, N1322, F1522 Cabinet Layout .
  • Page 3: Installation

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Installation: This machine is designed to be used indoors, in a The quality of the water supplied to the ice machine controlled environment. Operation outside the limits will have an impact on the time between cleanings listed here will void the warranty.
  • Page 4: Location

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Location: While the machine will operate satisfactorily within Bin compatibility the listed air and water temperature limits, it will produce more ice when those temperatures are All models have the same footprint: 22 inches wide nearer the lower limits.
  • Page 5: N0422, F0522, N0622, F0822, N0822 Cabinet Layout

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual N0422, F0522, N0622, F0822 Cabinet Layout 58.1 55.9 22.89 22.00 REF. 31.8 12.50 ULTRA SONIC BIN LEVEL SENSOR OPTIONAL [58.5] 23.00 PLAN VIEW 24.00 REF. 41.9 16.50...
  • Page 6: N0922, F1222, N1322, F1522 Cabinet Layout

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual N0922, F1222, N1322, F1522 Cabinet Layout 55.9 58.1 22.00 REF. 22.89 31.8 12.50 ULTRA SONIC BIN LEVEL SENSOR OPTIONAL [68.6] 27.00 24.00 LOUVER AND PLAN VIEW REF.
  • Page 7: Unpacking & Install Prep

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Unpacking & Install Prep Remove the carton from the skid. Check for hidden Panel Removal freight damage, notify the carrier immediately if any is found. Retain the carton for the carrier’s inspection.
  • Page 8: Water - Air Or Water Cooled

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Water - Air or Water Cooled The water supply for ice making must be cold, potable water. There is a single ” male flare potable water connection on the back panel. Water...
  • Page 9: Electrical - All Models

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Electrical - All Models The machine does not include a power cord, one Connect electrical power to wires inside the must be field supplied or the machine hard wired to junction box in the back of the cabinet.
  • Page 10: Refrigeration - Remote Condenser Models

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Refrigeration - Remote Condenser Models Remote condenser models have additional installation needs. The correct remote condenser fan and coil must be connected to the ice making head. Liquid and discharge tubing connections are on the back of the ice machine cabinet.
  • Page 11: Remote Condenser Location - Limits

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Remote Condenser Location - Limits Use the following for planning the placement of the Do NOT: condenser relative to the ice machine • Route a line set that rises, then falls, then Location Limits - condenser location must not rises.
  • Page 12: For The Installer: Remote Condenser

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual For The Installer: Remote Condenser Locate the condenser as near as possible to the interior location of the ice machine. Allow it plenty of space for air and cleaning: keep it a minimum of two feet away from a wall or other rooftop unit.
  • Page 13: Precharged Line Routing - Remote Only

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Precharged Line Routing - Remote Only Do not connect the precharged tubing until all Caution: Do NOT kink the refrigerant tubing while routing and forming of the tubing is complete. See routing it.
  • Page 14: Coupling Instructions - Remote Only

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Coupling Instructions - Remote Only The couplings on the ends of the pre-charged line loose in the refrigeration system. Note: As the sets are self-sealing when installed properly.
  • Page 15: Water - Remote Models

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Water - Remote Models The water supply for ice making must be cold, Drains - use rigid tubing: Connect the drain tube to potable water. There is a single ”...
  • Page 16: Final Check List

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Final Check List After connections: Control Operation 1. Wash out the bin. If desired, the interior of the Use and Operation bin could be sanitized. Once started, the ice machine will automatically 2.
  • Page 17: Initial Start Up And Maintenance

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Initial Start Up and Maintenance 1. Turn the water supply on. Sensor Cleaning: Every time the scale is removed. 2. Switch the electrical power on. Confirm voltage Top bearing check: At least twice a year or every is correct for the model.
  • Page 18: Maintenance: Scale Removal And Sanitation

    Discard or melt all ice made during 6. Remove the water reservoir cover. the previous step. 7. Mix a solution of 8 ounces of Scotsman Clear 13. To sanitize the water system, mix a locally One Scale Remover and 3 quarts of 95-115 approved sanitizing solution.
  • Page 19: Maintenance: Check Top Bearing

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Maintenance: Check Top Bearing This task should only be done by a qualified service technician Breaker Cover The bearing in the breaker should be checked at least two times per year.
  • Page 20: Bearing Service

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Bearing Service This task should only be done by a qualified service technician If the grease is uniformly white, no further action is needed. If very gray, rusty, wet or has any embedded metal, have the bearing replaced.
  • Page 21: Maintenance: Sensors

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Maintenance: Sensors The control that senses bin full and empty is a The ice machine senses water by a probe located photo-electric eye, therefore it must be kept clean near the water reservoir.
  • Page 22: Options

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual Options Vari-Smart Dispenser applications - Nugget ice only: Optional adjustable ice level control (KVS) Set the adjustment knob to Full When this option is present there is an adjustment...
  • Page 23: What To Do Before Calling For Service

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 Air, Water or Remote User Manual • What to do before calling for service Does not make ice • Auger motor overload Normal Operation: • High discharge pressure. • Low refrigeration system pressure.
  • Page 24 SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway, Vernon Hills, IL 60061 800-533-6006 www.scotsman-ice.com 17-3222-01...

This manual is also suitable for:

F0822F1222F1522N0422N0622N0922 ... Show all

Table of Contents