Electrical - All Models - Scotsman FB1222 Installation And User Manual

Modular flaked & nugget ice machines
Table of Contents

Advertisement

NB0622, NB0922, FB1222, NB1322
Installation and Use

Electrical - All Models

The machine does not include a power cord, one
must be field supplied or the machine hard wired to
the electrical power supply.
The junction box for the power cord is on the back
panel. See detail below.
Refer to the dataplate on the machine for minimum
circuit ampacity and determine the proper wire size
for the application. The dataplate (on the back of
the cabinet) also includes the maximum fuse size.
Dimensions
Model
w" x d" x h"
NB0622A-1
same
NB0922A-32
22 x 24 x 27
FB1222A-32
same
NB1322A-32
same
Junction
Box
Ground Wire
Cover
Connection
Install
Black
Strain
White
Relief
Ground
Reference: Electrical Detail
Voltage
Volts/Hz/Phase
115/60/1
208-230/60/1
208-230/60/1
208-230/60/1
Power
Supply
Wires
August 2011
Connect electrical power to wires inside the
junction box in the back of the cabinet. Use a strain
relief and connect a ground wire to the ground
screw.
Remote models power the condenser fan motor
from marked leads in the junction box.
Do not use an extension cord. Follow all local and
national codes.
Condenser
Min Circ
Type
Ampacity
Air
18.3
Air
12.5
Air
12.5
Air
19.1
Page 8
Max Fuse Size or HACR
Type Circuit Breaker
25
15
15
30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nb0922Nb0622Nb1322