For The Installer: Remote Condenser

Locate the condenser as near as possible to the
interior location of the ice machine. Allow it plenty
of space for air and cleaning: keep it a minimum of
two feet away from a wall or other rooftop unit.
Note: The location of the condenser relative to the
ice machine is LIMITED by the specification on the
prior page.
Roof penetration. In many cases a roofing
contractor will need to make and seal the hole in
the roof for the line sets. The suggested hole
diameter is 2 inches.
Meet all applicable building codes.
Roof Attachment
Install and attach the remote condenser to the roof
of the building, using the methods and practices of
construction that conform to the local building
codes, including having a
roofing contractor secure
the condenser to the roof.
To Remote Condenser
Pre-Charged
Refrigeration
Tubing