For The Installer: Remote Condenser
Locate the condenser as near as possible to the
interior location of the ice machine. Allow it plenty of
space for air and cleaning: keep it a minimum of two
feet away from a wall or other rooftop unit.
Note: The location of the condenser relative to the ice
machine is LIMITED by the specification on the prior
Power Supply from
page.
Ice Machine
Roof penetration
In many cases a roofing contractor will need to make
and seal the hole in the roof for the line sets. The
suggested hole diameter is 2 inches.
Meet all applicable building codes.
Roof Attachment
Install and attach the remote condenser to the roof
Remote Condenser
of the building, using the methods and practices of
construction that conform to the local building codes,
including having a roofing contractor secure the
Refrigeration
condenser to the roof
To Remote Condenser
connections
Brazing required
Refrigeration
Tubing
*reference page 4 for more detailed layout of rear panel connections
November 2020
Page 10