Mantel, Adding Extra Support - Heat & Glo Heat&Glo RUTHERFORD-36 Owner's Manual

Installation and operation
Table of Contents

Advertisement

F. Mantel, Adding Extra Support
If extra support for the mantel is needed across the front of
the fi replace:
Obtain a piece of top/bottom track used in metal
framing.
Cut the track to 51 7/8 in. (1318 mm) long.
Notch each end of the track 2 in. (51 mm). See
Figure 12.12.
Place the track into the notches (shown in Figure 12.13)
on the front standoffs and secure to the framing on both
sides of the fi replace (Figure 12.14).
Use drywall screws to fasten the mantel to the metal
framing.
2 in.
(51 mm)
Figure 12.12 Notch the Metal Track
Figure 12.13 Notch in Standoffs
46
Notches
(both ends)
Notches
in standoffs
Heat & Glo • RUTHERFORD-36 • 4059-341 Rev D • 03/09
Figure 12.14 Secure to Framing
Secure to
framing

Advertisement

Table of Contents