F. Mantel, Adding Extra Support
If extra support for the mantel is needed across the front of
the fi replace:
•
Obtain a piece of top/bottom track used in metal
framing.
•
Cut the track to 51 7/8 in. (1318 mm) long.
•
Notch each end of the track 2 in. (51 mm). See
Figure 12.12.
•
Place the track into the notches (shown in Figure 12.13)
on the front standoffs and secure to the framing on both
sides of the fi replace (Figure 12.14).
•
Use drywall screws to fasten the mantel to the metal
framing.
2 in.
(51 mm)
Figure 12.12 Notch the Metal Track
Figure 12.13 Notch in Standoffs
46
Notches
(both ends)
Notches
in standoffs
Heat & Glo • RUTHERFORD-36 • 4059-341 Rev D • 03/09
Figure 12.14 Secure to Framing
Secure to
framing