Maintainance and Service

A. Disposal of Ashes
Frequency: When they reach bottom of grate
By: Homeowner
WARNING! Risk of Fire! Ashes could contain hot embers.
Place ashes in a metal container with a tight-fi tting lid.
The closed container should be placed on a non-
combustible fl oor or on the ground, well away from all
combustible materials, pending fi nal disposal.
If the ashes are disposed of by burial in soil or otherwise
locally dispersed, they should be retained in the closed
container until all cinders have thoroughly cooled.
Remove screws,
lift top cover.
Chimney
TR11/TR11T/TR11-TV
Round Termination Cap
Figure 3.1
Chimney & Termination Cap Cleaning
Top Cover
Cap
Cap
Slip
Section
Square Termination Cap
Heat & Glo • RUTHERFORD-36 • 4059-341 Rev D • 03/09
B. Chimney Inspection/Cleaning
Frequency: At least twice a year during heating season or
as recommended by a certifi ed chimney sweep
By: Certifi ed chimney sweep
WARNING! Risk of Fire! Ignited creosote is extremely
HOT. Prevent creosote buildup.
Refer to Figure 3.1 to remove/reinstall termination caps.
Creosote - Formation and Need for Removal
When wood is burned slowly, it produces tar and other
organic vapors, which combine with expelled moisture to
form creosote. The creosote vapors condense in the rela-
tively cool chimney fl ue of a slow-burning fi re. As a result,
creosote residue accumulates on the fl ue lining. When
ignited this creosote makes an extremely hot fi re.
WARNING! Risk of Fire! A chimney fi re can permanently
damage your chimney system and nearby structures.
In the event of a chimney fi re, Hearth & Home Technolo-
gies Inc. recommends
replacement of the chimney, and
inspection of the adjacent structure to the provisions of
NFPA Level III inspection criteria
The chimney shall be inspected at least twice a year during
the heating season to determine when a creosote buildup
has occurred.
When creosote has accumulated it shall be removed to
reduce the risk of a chimney fi re.
Remove 4 screws
and lift top pan off.
ST1175
Remove 2 screws from
the front and back and
lift the top off.
TCT1175
Terra Cotta
Termination Cap
11