Chimney Assembly
NOTICE: Chimney performance may vary.
•
Trees, buildings, roof lines and wind conditions affect
performance.
•
Chimney height may need adjustment if smoking or
overdraft occurs.
Figure 8.1 Typical Chimney System - Guidelines for Chimney System Installation
24
Chimney must extend
beyond combustible
roof structure
Maintain minimum
height of chimney
above roof
Install roof flashing
according to minimum
requirements
Offsets/returns
may not exceed
30° from vertical
Lock chimney
sections together
firmly to resist
movement
Heat & Glo • RUTHERFORD-36 • 4059-341 Rev D • 03/09
Termination Cap
Additional
support for
tall chimneys
Storm Collar
Maintain minimum
clearances to
combustibles as
specified
Support straps for offsets
(not shown) must be
secured to adequate framing
Offsets/returns must be
secured with the screws
provided (outer pipe only)
Attic shield not shown
(see Figure 6.2)
Ceiling firestops
are required where
chimney passes
through ceiling or
floor