B. Install Fireplace & Chimney
Install as per Sections 7 and 8.
C. Install Chase Top
You MUST use a chase top in a chase installation. Chase
tops are available from your Heat & Glo dealer or may
be field constructed.
Include a turndown and drip edge to prevent water from
seeping into the chase.
Include a 2 in. (51 mm) soldered, caulked or spun collar
around pipe opening to keep water out.
Provide a 1/8 in. (3 mm) gap around the flue pipe.
Slope the chase top downward away from the
opening.
CAUTION! DO NOT caulk the pipe to the chase top
collar.
Caulk all seams to prevent leaks.
Refer to Figure 9.4.
Heat & Glo • BAY-40, PIER-40 • 34977 • Rev AA 1/11
Slope Downward
(1/4 in. per foot
minimum)
Figure 9.3
Chase Top Construction
2 in. (51 mm) Collar
on Chase Top
Turn-down
Drip Edge
Chase
.018 (26 ga) min.
Galvanized
Chase Top