Command: &En XON/XOFF Pacing Control
Values:
n = 12 or 13
Default:
12
Description:&E12 Disables XON/XOFF pacing.
&E13 Enables XON/XOFF pacing. (&K4 must also be set)
Note: &E13 has no effect if hardware control (&K3) is selected.
Caution: Do not enable pacing unless you need it. Some applications may not work if pacing is enabled.
Command: &Dn Data Terminal Ready (DTR) Control
Values:
n = 0, 1, 2, or 3
Default:
2
Description:&D0 Modem ignores the true status of the DTR signal and responds as if it is always on.
&D1 If DTR drops while in online data mode, the modem enters command mode, issues an OK, and
remains connected.
&D2 If DTR drops while in online data mode, the modem hangs up. If the signal is not present, the
modem will not answer or dial.
&D3 If DTR drops, the modem hangs up and resets as if an ATZ command were issued.
Command: &Fn Load Factory Settings
Values:
n = 0
Default:
None
Description:&F0 Load factory settings as active configuration.
Note: See also the Z command.
Command: &Gn V.22bis Guard Tone Control
Values:
n = 0, 1, or 2
Default:
0
Description:&G0 Disable guard tone.
&G1 Set guard tone to 550 Hz.
&G2 Set guard tone to 1800 Hz.
Note: The &G command is not used in North America.
Command: &Jn Auxiliary Relay Control
Values:
n = 0
Default:
0
Description:&J0 The auxiliary relay is never closed.
&J1 Not supported—responds ERROR.
Command: &Kn Flow Control Selection
Values:
n = 0, 3, or 4
Defaults:
3
Description:&K0 Disable flow control.
&K3 Enable CTS/RTS hardware flow control.
&K4 Enable XON/XOFF software flow control.
Command: &Mn Communications Mode
Values:
n = 0
Defaults:
0
Description:&M0 Asynchronous mode.
&M1 Not supported—responds ERROR.
Chapter 3 - AT Commands, S-Registers and Result Codes