Graco FinishPro 290 Operation Manual page 39

Airless/air-assisted sprayer 2800 psi (193 bar, 19.3 mpa) maximum working pressure airless spraying
Hide thumbs Also See for FinishPro 290:
Table of Contents

Advertisement

Problem
Air compressor does not run
Poor air spray pattern
Water in pattern
313797C
What To Check
(If check is OK, go to next check)
1. Power/function selector switch
2. Voltage to compressor below 105
Vac for 110 - 120 Vac models or
below 210 Vac for 240 Vac models
3. Loose power connections
4. Excessive head pressure
(compressor hums)
5. Excessive head pressure
(compressor hums)
6. Fuse. Check replaceable fuse
on compressor control board.
7. Compressor thermal switch is
open. Ensure ambient temperature
is below 115 °F (46 °C).
8. Low compressor performance.
1. Air cap or air manifold air ports
clogged.
2. Air cap worn.
3. Worn spray tip.
1. Water in air line.
基本故障排除
Basic Troubleshooting /
What To Do
(When check is not OK, refer to this column)
Set function selector switch to ON; replace switch.
Try another outlet. Reduce extension cord length
or increase extension cord gauge.
Verify all connections are firm.
Moisture frozen in air supply line.
Wait for air pressure to bleed to zero.
Replace fuse after completing motor inspection,
page 62.
Move sprayer to shaded, cooler area.
Worn compressor; repair compressor with
Compressor Service Kit, page 62.
Soak in solvent to clean.
Replace air cap.
Relieve pressure, page 15. Replace tip. Refer to gun
instruction manual, 313347.
Add Water Separator Kit 257824 to air line.
기본적인 문제 해결
/
39

Advertisement

Table of Contents
loading

Table of Contents